Ford · Model Report
Ford F-1501991
Showing safety data for the 1991 model year only.
Ford · Model Report
Showing safety data for the 1991 model year only.
THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. VEHICLE DESCRIPTION: 1990-1993 FORD F-SERIES VEHICLES EQUIPPED WITH DUAL FUEL TANKS AND 4.9, 5.0,5.8, OR 7.5 LITER GASOLINE FUELED ENGINES. SOME VEHICLES CAN EXPERIENCE A CROSS TANK FUEL FLOW CONDITION DUE TO A DAMAGED CHECK VALVE IN THE FUEL PUMP/SENDER ASSEMBLY. FUEL MAY BE SUPPLIED FROM ONE TANK AND SOME OR ALL OF THE UNUSED FUEL MAY BE RETURNED TO THE OTHER TANK.
THIS IS NOT A SAFETY RECALL IN ACCORDANCE WITH THE SAFETY ACT. HOWEVER, IT IS DEEMED A SAFETY IMPROVEMENT CAMPAIGN BY THE AGENCY. EQUIPMENT DESCRIPTION: FORD IS REPLACING ALL FIRESTONE WILDERNESS AT 15, 16, AND 17 INCH TIRES MOUNTED ON FORD TRUCKS AND SUVS. FORD REPORTS TREAD SEPARATION CAN OCCUR DUE TO A COMBINATION OF THE SENSITIVITY OF THE TIRE DESIGN TO STRESS, AGING, AND MANUFACTURING DIFFERENCES BETWEEN PLANTS. FORD IS REPLACING THESE TIRES TO PREVENT POSSIBLE PREMATURE TIRE FAILURE. VEHICLE DESCRIPTION: THE VEHICLES LISTED BELOW MAY HAVE BEEN ORIGINALLY EQUIPPED WITH FIRESTONE WILDERNESS AT TIRES OR MAY HAVE HAD WILDERNESS AT TIRES INSTALLED DURING THE FIRESTONE RECALL LAUNCHED IN AUGUST 2000. CERTAIN 1991 THROUGHT 2002 FORD EXPLORER CERTAIN 2001 THROUGHT 2002 EXPLORER SPORT, AND SPORT TRAC CERTAIN 1997 THROUGH 2002 MERCURY MOUNTAINEER CERTAIN 1991 THROUGH 2001 RANGER CERTAIN 1999 THROUGH 2001 EXPEDITION CERTAIN 1991 THROUGH 1994, AND 1997 MODEL YEAR F-SERIES CERTAIN 1991 THROUGH 1994 BRONCO NOTE: BOTH ORIGINAL EQUIPMENT AND REPLACEMENT TIRES ARE AFFECTED.
TIRE DESCRIPTION: FIRESTONE WILDERNESS AT, SIZE P235/75R15, PRODUCED AT THE DECATUR, ILLINOIS TIRE PLANT AND ALL FIRESTONE RADIAL ATX AND RADIAL ATX II TIRES, SIZE P235/75R15. OPERATION OF THESE TIRES AT LOW INFLATION PRESSURES, HIGH SPEED, AND IN HOT WEATHER, CAN CONTRIBUTE TO SEPARATION OF THE TIRE TREAD.
THE IGNITION SWITCH COULD EXPERIENCE AN INTERNAL SHORT CIRCUIT.
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE.
The contact owns a 1991 Ford F-150. The contact stated that while driving at an undisclosed speed, the rear fuel tank gauge began indicating that the rear tank was losing fuel abnormally fast. After a visual inspection, the contact observed that fuel was flowing from the rear fuel tank into the front fuel tank. No warning lights were illuminated. The vehicle was taken to the dealer, who diagnosed a failure with the fuel pump assembly check valve; however, the dealer declined to attempt to repair the vehicle due to the age of the vehicle. The vehicle was not repaired. After investigating the failure, the contact related the failure to NHTSA Campaign Number: 93V125000 (Fuel System, Gasoline), but was unaware if the VIN was ever included in the recall. The manufacturer was notified of the failure, a case was opened, and the contact was later informed that the VIN was included in the recall and had been repaired already. The failure mileage was 112,000.
No injuries · No fire · No crash
THE TRUCK WONT CRANK. WHEN THE KEY IS TURNED OFF AND REMOVED SOME ELECTRICAL SYSTEMS STILL WORK AND CAUSE SMOKING. I HAVE HAD TO DISCONNECT THE BATTERY IN FEAR THE TRUCK WILL BURN DOWN. FORD WAS CONTACTED ABOUT THE ISSUE AND SAID THEY CANT DO ANYTHING BECAUSE THEIR RECORDS FOR RECALLS ONLY GO 10 YEARS. EVEN THOUGH THE TRUCK HAS LESS THAN 84000 MILES ON IT.
No injuries · No fire · No crash
FUEL SPILLING OUT AROUND NECK WHILE PARKED AT WORK, ALSO REAR FUEL TANK PUMPING GAS INTO FRONT GAS TANK WHILE DRIVING.... *TR
No injuries · No fire · No crash
TL* THE CONTACT OWNS A 1991 FORD F-150. THE CONTACT STATED THAT ONE OF THE TANKS IN THE VEHICLE WOULD NOT WORK AND CAUSED THE VEHICLE TO STALL. THE VEHICLE WAS TAKEN TO AN INDEPENDENT MECHANIC, BUT COULD NOT BE REPAIRED. THE DETAILS OF THE DIAGNOSTIC TEST COULD NOT BE PROVIDED. THE VIN WAS NOT INCLUDED IN NHTSA CAMPAIGN NUMBER: 01L008000 (FUEL SYSTEM, GASOLINE). THE MANUFACTURER WAS NOTIFIED OF THE FAILURE. THE APPROXIMATE FAILURE MILEAGE WAS 123,000. UPDATED 01/05/17*LJ
No injuries · No fire · No crash
WHILE THE ENGINE IS RUNNING, THE DUAL TANKS CROSS-FLOW INTO ONE ANOTHER. ONE TANK HAS OVER-FILLED THE OTHER TANK AND VISA VERSA TO INCLUDE SPILLAGE. I HAVE CONTACTED THE LOCAL DEALER AND FORD ABOUT IT BUT THEY SAY THEY CAN'T DO ANYTHING FOR ME AS FAR AS A RECALL IS CONCERNED EVEN THOUGH THIS ISSUE WAS A SAFETY RECALL ISSUE IN THE PAST. I DO NOT KNOW IF THE PREVIOUS OWNER ADDRESSED THE RECALL BUT IT IS A PROBLEM RIGHT NOW. WHEN I PURCHASED THE TRUCK, I DIDN'T KNOW IT HAD A CROSS-FLOW PROBLEM UNTIL SOMEONE TOLD ME SOMETHING WAS LEAKING FROM UNDER MY TRUCK. SINCE THEN, I HAVE NOTICED THAT THE FUEL GAUGE GOES DOWN QUICKER THAN IT SHOULD AND WHEN I SWITCH TANKS, THE OTHER TANK HAS MORE FUEL THAN IT DID. THIS ISSUE HAPPENS REGARDLESS IF IN MOTION OR STANDING STILL. IF THE TRACK WAS FIXED VIA A RECALL, THEY OBVIOUSLY DIDN'T DO IT RIGHT OR THE "FIX" DIDN'T FIX THE PROBLEM. I CAN NOT AFFORD TO FIX THIS ISSUE EVEN THOUGH IT SHOULD HAVE BEEN FIXED THROUGH THE RECALL ALREADY.
No injuries · No fire · No crash