2022-2023 Audi Q5 Q3 Q7 MIL On for DTC P240700

If your 2022-2023 Audi Q5 e-quattro, Q3, or Q7 has an illuminated Malfunction Indicator Lamp (MIL) and stores DTC P240700, Audi Technical Service Bulletin 2071770/6 provides a software update solution for the EVAP system leakage diagnosis pump current fluctuating.

ByAhmet Topcu — Founder & Editor-in-Chief2022 Audi Q7
2022 Audi Q7 — Audi Q5 Q3 Q7 MIL P240700
Editorial illustration generated for this article.
P2407P2407002071770/601 24 20 2071770/6"EVAP emission control system leakage diagnosis pump current fluctuating""MIL is illuminated"Audi Q5 e-quattro P240700Audi Q3 P240700Audi Q7 P240700Engine Control Module J623
Audi Q3
2022
Audi Q5 e
2023

Symptoms

Owners of affected Audi vehicles may notice that the Malfunction Indicator Lamp (MIL) is illuminated on their dashboard. Typically, no other relevant error messages or symptoms are logged in the engine control unit when this specific condition occurs.

Fault Codes / DTCs

When diagnosing the issue, workshops will find the following Diagnostic Trouble Code (DTC) stored in the Engine Control Module, identified as -J623- (address word 0001):

  • DTC P2407 (P240700): "EVAP emission control system leakage diagnosis pump current fluctuating"

Diagnosis / Trigger Conditions

The root cause of the illuminated MIL and the stored DTC P240700 is identified as overly sensitive On-Board Diagnostics (OBD). This heightened sensitivity leads to the erroneous detection of a fluctuating current in the EVAP (Evaporative Emission Control System) leak detection pump, even when no actual fault exists. This condition triggers the Malfunction Indicator Lamp and logs the P240700 fault code, prompting owners to seek service for their Audi Q5 Q3 Q7 MIL P240700 issue.

Repair Procedure Summary

The primary repair for the Audi Q5 Q3 Q7 MIL P240700 issue involves updating the software in the Engine Control Module (-J623-, address word 0001). Technicians must first consult Technical Service Bulletin 2011732, which outlines the Software Version Management (SVM) operating instructions. The update process requires using a VAS tester equipped with the current version of ODIS (Windows 10). During the update, the SVM action code, such as "6" for certain Q5 PHEV models, will be entered to ensure the correct new software version is installed. This new software specifically addresses the over-sensitive OBD diagnostics that trigger the P240700 fault code, thereby resolving the illuminated MIL. The bulletin lists specific old and new software part numbers and versions for the Q7 2.0l, Q3, and Q5 PHEV models, ensuring the correct update is applied based on the vehicle's model year.

Required Tools or Parts

To perform the necessary software update, service technicians will require the following specialized equipment:

  • VAS 6160/VAS 6150: This is a VAS tester that must be running the current version of ODIS (Windows 10) software to successfully execute the Engine Control Module update.

Warranty Information

This software update, identified by Audi Technical Service Bulletin 2071770/6, is covered under Audi's warranty for vehicles up to 48 months or 50,000 miles, whichever occurs first, falling under Claim Type 110. For Audi Certified Pre-Owned (CPO) vehicles, the repair is covered under Claim Type G10, though owner verification is required. The specific service number for this bulletin is 2048, and the damage code to be used for claims is 0040. Labor operations include "Software Update (Includes checking for DTCs)" with labor code 0151 0000, and "Charge Battery" with labor code 2706 8950. The diagnostic time is determined by the diagnostic protocol, with a maximum allowance of 50 Technical Units (TU). Importantly, no allowance is provided for road tests either before or after the service, indicating that the diagnostic and repair process is primarily software-based and does not typically require extensive driving verification.

Important Warnings

  • "If the vehicle is outside of any warranty, this Technical Service Bulletin is informational only." This means that owners of vehicles no longer covered by warranty may be responsible for the costs associated with this repair.
  • All warranty claims submitted for payment must strictly adhere to the guidelines outlined in the Audi Warranty Policies and Procedures Manual.

Source: NHTSA ID 11002109

Frequently Asked Questions

What does DTC P240700 mean for my Audi?
DTC P240700, or "EVAP emission control system leakage diagnosis pump current fluctuating," indicates that the Engine Control Module has detected an abnormal current fluctuation in the EVAP system's leak detection pump. This is often due to overly sensitive diagnostics rather than an actual component failure.
Which Audi models are affected by the MIL on with DTC P240700?
This issue primarily affects 2022-2023 Audi Q5 e-quattro, 2022 Audi Q3, and 2022 Audi Q7 vehicles. Owners of these models may experience the Malfunction Indicator Lamp (MIL) illuminating on their dashboard.
How is the "EVAP emission control system leakage diagnosis pump current fluctuating" issue resolved?
The issue is resolved by updating the software in the Engine Control Module (-J623-) using a VAS tester with the latest ODIS software, as detailed in Audi Technical Service Bulletin 2071770/6. This software update corrects the over-sensitive OBD diagnostics.
Will I have to pay for the software update to fix the MIL on my Audi?
If your vehicle is within the 48 months/50,000 miles warranty period or is an Audi Certified Pre-Owned vehicle, the software update should be covered. If your vehicle is outside of warranty, this TSB is informational only, and you may be responsible for the repair costs.

Altre revisioni di questo TSB

Related Articles

2017-2026 Audi Q7/SQ7 Second Row Seat Noise TSB

If your 2017-2026 Audi Q7 or SQ7 has a creaking or rattling noise from the second-row seats, Technical Service Bulletin 2060719/5 details a repair procedure. The noise is caused by friction between the seat lock handle and the locking mechanism. This TSB outlines how technicians should adjust the…

2022-2023 Audi Q7/Q5/Q3 MIL On for DTC P240700

Audi has issued Technical Service Bulletin 2071770/8 for 2022-2023 Q3, Q5, Q5 PHEV, and Q7 models experiencing a Check Engine Light (MIL) and diagnostic trouble code P240700. This TSB addresses an overly sensitive OBD diagnostic system related to the EVAP emission control system.

2021-2024 Audi Technical Analysis List for Various Issues

This Audi On-Car Analysis List, dated July 15, 2024, provides guidance for technicians on diagnosing and addressing various common issues across 2021-2024 Audi models. Topics include airbag warning lights (DTCs B101704, B103604, B12251B), MIB3 system problems, roof panel button malfunctions, noisy…

2022-2023 Audi Q3, Q5, Q7 MIL On DTC P240700

Audi has released Technical Service Bulletin (TSB) 2071770/7 for 2022-2023 Q3, Q5, and Q7 models experiencing a Malfunction Indicator Lamp (MIL) illumination with DTC P240700. This is due to overly sensitive OBD diagnostics for the EVAP system.

2022-2023 Audi Q5 PHEV, Q3, Q7 MIL On with DTC P240700

Audi has released Technical Service Bulletin 2071770/6 to address a Malfunction Indicator Lamp (MIL) illumination accompanied by Diagnostic Trouble Code P240700 (EVAP emission control system leakage diagnosis pump current fluctuating) in 2022-2023 Audi Q5 PHEV, Q3, and Q7 models. A software update…