Service-Bulletin

2022-2023 Audi Q7/Q5/Q3 MIL On for DTC P240700

Audi has issued Technical Service Bulletin 2071770/8 for 2022-2023 Q3, Q5, Q5 PHEV, and Q7 models experiencing a Check Engine Light (MIL) and diagnostic trouble code P240700. This TSB addresses an overly sensitive OBD diagnostic system related to the EVAP emission control system.

Byeditor marcus weber2022 Audi Q7
2022 Audi Q7 — Audi Q7 P240700
Editorial illustration generated for this article.
P2407P240700MIL is illuminatedEVAP emission control system leakage diagnosis pump current fluctuatingAudi TSB 2071770/8Audi TSB 24-22Audi PSS 2066675Audi TSB 2011732Engine Control Module J623SVM action code 01A320
Audi Q3
2022
Audi Q5
2022–2023
Audi Q5 e
2023
Audi Q7
2023

Audi has released Technical Service Bulletin (TSB) 2071770/8 to address an issue affecting certain 2022-2023 Audi Q3, Q5, Q5 PHEV, and Q7 models. Owners of these vehicles may experience an illuminated Check Engine Light (MIL) accompanied by a specific diagnostic trouble code. This TSB supersedes a previous bulletin, Group 01 number 24-22, dated May 14, 2024, and also replaces Pending Service Solution (PSS) TSB 2066675: 01 PSS MIL on DTC P240700 Evap leak detection pump circuit. The TSB itself has undergone several revisions, with revision 8 adding models to the SVM table, revision 7 correcting the SVM table on May 15, 2024, and revision 6 updating the header and SVM table for the 2022 Q7 on May 10, 2024.

Symptoms

Owners will primarily notice one key symptom:

  • The "MIL is illuminated" (Malfunction Indicator Lamp, commonly known as the Check Engine Light).

Fault Codes / DTCs

When scanned, the Engine Control Module (-J623-, address word 0001) may store the following diagnostic trouble code:

Code Description
P2407 "EVAP emission control system leakage diagnosis pump current fluctuating"
P240700 "EVAP emission control system leakage diagnosis pump current fluctuating"

No other relevant event memory entries are typically logged in the engine control unit when this specific issue is present.

Diagnosis / Trigger Conditions

The root cause of the illuminated MIL and the Audi Q7 P240700 fault code is an overly sensitive On-Board Diagnostics (OBD) system. The diagnostic routine for the EVAP emission control system's leakage detection pump current is too sensitive, leading to false positive fault detections. This sensitivity can cause the system to incorrectly flag a problem when none exists.

Important Warnings for High-Voltage Vehicles

For Audi Q5 PHEV models, which are equipped with high-voltage components, a critical step must be followed during the software update:

  • The high-voltage cable must be removed BEFORE the SVM code is entered. This prevents the high-voltage battery from charging during the software update. Charging the high-voltage battery during a software update can cause damage to the high-voltage components.

Repair Procedure Summary

The solution for the Audi Q7 P240700 and related models involves updating the software in the Engine Control Module (-J623-, address word 0001). This new software addresses the overly sensitive OBD diagnostics, preventing the incorrect triggering of the P240700 DTC.

Technicians will need to follow all instructions outlined in TSB 2011732, titled "00 Software Version Management (SVM), operating instructions." The update is performed using SVM action code 01A320. The specific software part numbers and versions to be updated are as follows:

  • Q7 2.0l MY2023: Old Software Part Number 4M0.906.259.AB (Versions 0002, 0003, 0004) to New Software Part Number 4M0.906.259.AB (Version 0005 or higher).
  • Q7 2.0l MY2022: Old Software Part Number 4M0.906.259.AE (Version 0001) to New Software Part Number 4M0.906.259.AE (Version 0002 or higher).
  • Q3 MY2022: Old Software Part Number 83A.906.259.D (Version 0001) to New Software Part Number 83A.906.259.D (Version 0002 or higher).
  • Q5 MY2022: Old Software Part Number 80A.906.259.AB (Version 0002) to New Software Part Number 80A.906.259.AB (Version 0003 or higher).
  • Q5 PHEV MY2022: Old Software Part Number 80A.906.259.AA (Version 0001) to New Software Part Number 80A.906.259.AA (Version 0002 or higher).
  • Q5 MY2023: Old Software Part Number 80A.906.259.AE (Versions 0002, 0003) to New Software Part Number 80A.906.259.AE (Version 0004 or higher).
  • Q5 PHEV MY2023: Old Software Part Number 80A.906.259.AD (Version 0001) to New Software Part Number 80A.906.259.AD (Version 0002 or higher).

Required Tools

To perform the software update, technicians will need:

  • VAS 6160/VAS 6150: A VAS tester equipped with the current version of ODIS (running on Windows 10).

Warranty Information

For vehicles still under warranty, this service is covered under the following details:

  • Claim Type: If the vehicle is outside of any warranty, this Technical Service Bulletin is informational only.
  • Service Number: 2048
  • Damage Code: 0040
  • Labor Operations (With software Update):
    • Software Update: 0151 0010 (Refer to SRT for associated operations)
    • Software Update: 0151 0060 (Labor according to diagnostic log)
  • Labor Operations (Without software update):
    • GFF: 0150 0010 (Refer to SRT for associated operations)
    • GFF: 0150 0060 (Labor according to diagnostic log)
  • Road test prior to the service: No allowance, 0 TU
  • Road test after the service: No allowance, 0 TU

All warranty claims must adhere to the Audi Warranty Policies and Procedures Manual.

Owner Action

If you own a 2022-2023 Audi Q3, Q5, Q5 PHEV, or Q7 and are experiencing an illuminated Check Engine Light with the Audi Q7 P240700 diagnostic trouble code, you should contact an authorized Audi dealer. Inform them about Technical Service Bulletin 2071770/8. The dealer will be able to diagnose the issue and perform the necessary software update to resolve the overly sensitive OBD diagnostics.


Source: NHTSA ID: 10257321

Frequently Asked Questions

What does DTC P240700 mean for my Audi?
DTC P240700, often displayed as "EVAP emission control system leakage diagnosis pump current fluctuating", indicates that your Audi's Engine Control Module has detected an anomaly in the EVAP system's leak detection pump. In 2022-2023 Audi Q3, Q5, and Q7 models, this is typically due to overly sensitive diagnostic software, not a physical leak.
Which Audi models are affected by TSB 2071770/8?
Technical Service Bulletin 2071770/8 applies to 2022 Audi Q3, 2022-2023 Audi Q5 (including Q5 e quattro and Q5 Sportback), and 2022-2023 Audi Q7 models. These vehicles may experience a Check Engine Light (MIL) with DTC P240700.
How is the Audi P240700 issue resolved?
The issue is resolved by updating the software in the Engine Control Module (-J623-) using the SVM action code 01A320. This software update recalibrates the OBD diagnostics to prevent false detection of the EVAP system leakage pump current fluctuation. For high-voltage models like the Q5 PHEV, specific precautions regarding the high-voltage cable must be followed during the update.
Will I be charged for the software update to fix the Audi Q7 P240700 code?
If your vehicle is still under warranty, this software update is typically covered. Audi's warranty claim type for this service is informational only if the vehicle is outside of any warranty. It is best to confirm with your authorized Audi dealer regarding coverage. The Service Number for this operation is 2048 and the Damage Code is 0040.

Weitere Revisionen dieses TSB

Related Articles

2017-2026 Audi Q7/SQ7 Second Row Seat Noise TSB

If your 2017-2026 Audi Q7 or SQ7 has a creaking or rattling noise from the second-row seats, Technical Service Bulletin 2060719/5 details a repair procedure. The noise is caused by friction between the seat lock handle and the locking mechanism. This TSB outlines how technicians should adjust the…

2021-2024 Audi Technical Analysis List for Various Issues

This Audi On-Car Analysis List, dated July 15, 2024, provides guidance for technicians on diagnosing and addressing various common issues across 2021-2024 Audi models. Topics include airbag warning lights (DTCs B101704, B103604, B12251B), MIB3 system problems, roof panel button malfunctions, noisy…

2022-2023 Audi Q3, Q5, Q7 MIL On DTC P240700

Audi has released Technical Service Bulletin (TSB) 2071770/7 for 2022-2023 Q3, Q5, and Q7 models experiencing a Malfunction Indicator Lamp (MIL) illumination with DTC P240700. This is due to overly sensitive OBD diagnostics for the EVAP system.

2022-2023 Audi Q5 PHEV, Q3, Q7 MIL On with DTC P240700

Audi has released Technical Service Bulletin 2071770/6 to address a Malfunction Indicator Lamp (MIL) illumination accompanied by Diagnostic Trouble Code P240700 (EVAP emission control system leakage diagnosis pump current fluctuating) in 2022-2023 Audi Q5 PHEV, Q3, and Q7 models. A software update…

2022-2023 Audi Q5 Q3 Q7 MIL On for DTC P240700

If your 2022-2023 Audi Q5 e-quattro, Q3, or Q7 has an illuminated Malfunction Indicator Lamp (MIL) and stores DTC P240700, Audi Technical Service Bulletin 2071770/6 provides a software update solution for the EVAP system leakage diagnosis pump current fluctuating.

Comments

Be the first to comment.

Leave a comment

Comments are moderated and may take a moment to appear. Only your first name and the initial of your last name are shown publicly.

Verifying you are human...