- #10120107May 6, 2005ENGINE AND ENGINE COOLING:ENGINE:GASOLINE
WHILE DRIVING ALONG A SPARK PLUG WAS BLOWN OUT OF THE CYLINDER WITH THE INSUING LOUD BANGING SCARING THE DRIVER AND ALMOST CAUSING AN ACCIDENT. FORD DEALER RETHREADED SPARK PLUG HOLE AND REPLACED SPARK PLUG.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10120144May 6, 2005TIRES, TIRES:TREAD/BELT
DT: CONTACT HAS DEFECTIVE TIRES ON HER VEHICLE. THE TIRE MANUFACTURER IS CONTINENTAL TIRE COMPANY OF NORTH AMERICA INC. THE CONTACT STATED HER TIRE HAD A BULGE. THEN IN JUNE OF LAST YEAR TWO OF HER TIRES HAD A BULGE. SHE WENT TO THE DEALER AND HE DUPLICATED THE WEAR ON TIRES ,AND PUT SOME BRAND NEW TIRES ON HER VEHICLE. THE NEW TIRES WAS THE SAME MANUFACTURER. THE CONTACT ALSO STATED THAT ON APRIL 1ST OF THIS YEAR THE TRUCK BEGAN TO SHAKE, AND SHE SAW THAT THERE WAS A BULDE ON HER TIRES THE CONTACT WAS ON A BUSY HIGHWAY AND SHE COULD NOT CHANGE THE TIRES AT THE POINT SO SHE WAS GOING TO DRIVE TO A SAFE PLACE TO WERE SHE COULD CHANGE THE TIRES WHILE DRIVING DOWN THE HIGHWAY. THE TIRE BLEW AND DAMAGED HER VEHICLE. THE DEALER SAID THAT THEY WOULD NOT REPLACE THE TIRES BECAUSE HER VEHICLE WAS NO LONGER ON WARRENTY. SHE CONTACTED THE TIRE MANUFACTUER AND THEY SUGGESTED TO GO THROUGH HER INSURANCE AGENCY WHICH IS AAA. HER INSURANCE AGENCY SENT A MECHANICAL EVAULTOR, AND HE SAID THE TIRE WAS DEFECTIVE, AND HE SAID THAT IT HAD TIRE THREAD SEPERATION. THE MECHANICAL EVALUTOR STATED THAT 51 OTHER PEOPLE HAD FILED A COMPLAINT ABOUT THE SAME MANUFACTURER OF THESE TIRES. THE CONTACT HAS FILED AN COMPLAINT WITH FORD DEALER. AS OF RIGHT NOW THE CONTACT HAVE FOUR DEFECTIVE TIRES ON HER VEHICLE. THE TIRE LINE IS LT235/85R16.*AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10120152May 6, 2005FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK
DT: CONTACT OWNS A 1997 FORD F250. HE SAID THE VEHICLE STARTED RUNNING ROUGH SO HE TOOK IT TO THE SHOP, AND THEY CLEANED HIS FUEL INJECTION. THE TRUCK HAS TWO FUEL TANKS. THE FRONT FUEL TANK COMPLETELY QUIT WORKING THE REAR TANK WORKED. NOW HE SAYS THAT THE REAR TANK KEEPS ON FILLING THE FRONT TANK WITH GAS AND THERE IS SO MUCH PREASSURE FROM THE TANKS THAT GAS JUST STARTS RUNNING DOWN THE SIDE OF HIS VEHILCE AND WHEN HE OPENS THE GAS CAP FUEL STARTS SQUIRTING OUT HE SAID IT WOULD SQUIRT OUT ABOUT A HALF GALLON OF GAS. HIS SMOG CHECKEDWAS DO LAST WEEK AND SINCE HIS CHECK ENGINE LIGHT CAME ON THEY WILL NOT DO THE SMOG. THE DEALER SAID HE WAS MISSING A CHECK VALUVE BETWEEN THE FUEL TANKS AND THE DEALER TOLD HIM BOTH FUEL PUMPS HAD TO BE REPLACED.*AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10115411May 6, 2005SEAT BELTS:FRONT
VEHICLE EXPERIENCED DIFFICULTY WITH THE FRONT PASSENGER SIDE SEAT BELT. EACH TIME THE BRAKE WAS APPLIED TO TURN THE CORNER OR HITTING A BUMP IN THE ROAD THE SAFETY BELT WILL TIGHTEN. OWNER TOOK THE VEHICLE TO THE DEALER AND MANUFACTURER, AND WAS TOLD THAT THERE WAS NOTHING THEY COULD DO. *AK CONSUMER STATED THAT THE SEAT BELT LOCKED UP SO TIGHT THAT IT HURT HIS CHEST AND NECK. IT WOULD NOT RELEASE UNTIL THE SEAT BELT WAS UNBUCKLED. THE CONSUMER HAD TO LET IT RETRACT ALL THE WAY BACK, THEN REBUCKLE IT. *BF *NM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10115901May 6, 2005ELECTRICAL SYSTEM
WHILE DRIVING 20 MPH DRIVER NOTICED SMOKE COMING FROM UNDER THE HOOD. DRIVER PULLED OVER AND OPENED THE HOOD. SUDDENLY, VEHICLE CAUGHT ON FIRE. DRIVER WAS ABLE TO EXTINGUISH THE FIRE. VEHICLE WAS TOWED HOME. *AK THE CONSUMER HAD TO UNPLUG THE WIRES CONNECTED TO THE BRAKE MASTER CYLINDER TO STOP THE FIRE. NOW THE VEHICLE HAS NO AUTOMATIC CRUISE CONTROL. THE CONSUMER WAS TOLD BY LOCAL FORD SERVICE DEPARTMENT THAT THE FIRE WAS PROBABLY CAUSED BY THE CRUISE CONTROL SWITCH. THE MANUFACTURE HAS A RECALL ON F150 PICKUPS BUT NOT THE F250. THE PROBLEM HAS NOT BEEN REPAIRED AND THE WIRES HAVE BEEN LEFT UNPLUGGED FOR NOW. *BF *NM
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10119935May 5, 2005SERVICE BRAKES, HYDRAULIC:FOUNDATION COMPONENTS:HOSES, LINES/PIPING, AND FITTINGS
1999 FORD SD F250 CREW CAB LONG BED - DIESEL 6 SPD MANUAL: FRONT LEFT BREAK LINE CUT BY ENGINE PLASTIC SPLASH SHIELD. VEHICLE HAS 158K MILES NO RUST ON BREAK LINE BUT YOU CAN TELL THAT THE SPLASH SHIELD HAS BEEN RUBBING AGAINST THE METAL LINE. THERE IS OBVIOUSLY NOT ENOUGH CLEARANCE CREATED IN THE SPLASH SHIELD DESIGN. I AM NOT SURE IF THIS APPLIES ONLY TO DIESEL APPLICATIONS DUE TO THE HYDRAULIC POWER ASSIST . THIS ALMOST CREATED SERIOUS ACCIDENT WHEN THE LINE RUPTURED; WE WERE PULLING A 26 FT TRAILER WHICH HAD ELECTRIC BREAKS THAT HELP STOP THE VEHICLE BEFORE WE REACHED A MAJOR INTERSECTION. THE TRUCK HAD JUST BEEN IN FOR SERVICE AT THE FORD DEALERSHIP TWO DAYS BEFORE FOR VARIOUS SERVICES. THERE WAS NO WARNINGS THE BREAKS WERE FIRM AND THE THEY WENT WITHG ONE STEP OF LAST STEP ON THE BREAK. BREAK LINE WILL NEED TO BE REPLACED, MODIFIED TO MISS SPLASH SHEILD OR SPLASH SHEILD WILL NEED TO BE MODIFIED TO ASSURE CLREARANCE TO BREAK LINE.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10118803May 2, 2005ELECTRICAL SYSTEM:WIRING:FRONT UNDERHOOD
THERE WAS A FIRE UNDER THE HOOD . THE HOOD LATCH WOULD NOT WORK . THE FIRE DEPT EXTINGUISHED THE FIRE.
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10118690April 29, 2005ELECTRICAL SYSTEM, POWER TRAIN:AUTOMATIC TRANSMISSION:TORQUE CONVERTER, ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:EMISSION CONTROL:GAS RECIRCULATION VALVE (EGR VALVE)
WE PURCHASED A 2004 F250 TURBO DIESEL FROM MIKE BROWN FORD ON MAY 29, 2004 AND THE NIGHTMARE BEGAN. THE FIRST PROBLEM THE DEALERSHIP WIRED THE KEYLESS ENTRY INCORRECTLY AND HAD TO REPLACE THE WIRING HARNESS. AFTER THAT THE TRUCK BEGAN TO HAVE PROBLEMS WITH SURGING,AND DYING IN THE MIDDLE OF THE ROAD.. THE TRUCK HAS BEEN IN THE SHOP NUMEROUS TIMES, THEY HAVE REPLACED THE COMPUTER 9 TIMES, EXCHANGED THE EGR VALUES TWICE, THEY HAVE SLIPPED THE TORQUE CONVERTER, AND ALL TYPES OF REPROGRAMMED ON THE VARIOUS COMPONENTS ON THIS VEHICLE.. TO DATE THE TRUCK RUNS EXTREMELY BAD. MY WIFE DRIVES THIS VEHICLE, AND IS EXTREMELY SCARED OF THIS TRUCK, DO TO THE FACT THAT IT SURGES AND LOSES VACUUM AND SHOVES HER INTO INTERSECTIONS AT RED LIGHTS OR ANY OTHER TIMES SHE APPLIES THE BRAKES. THE VARIOUS FORD DEALERSHIPS ARE NO HELP THEY CONSTANTLY REPROGRAM AND RELEASE THE VEHICLE . NO MORE OR LESS THAN 5000 MILES THE VEHICLE STARTS IT AGAIN. WE BELIEVE THAT THIS VEHICLE IS DEFECTIVE AND EXTREMELY DANGEROUS TO DRIVE, SEEING HOW YOU NEVER NO WHEN IT WILL DIE, OR SURGE . WE FEEL THAT THIS VEHICLE IS A DANGER TO ANYONE WHO COMES IN CONTACT WITH .*AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10119233April 27, 2005VEHICLE SPEED CONTROL:CRUISE CONTROL
VEHICLE WAS PARKED IN THE GARAGE FOR ABOUT 15 HOURS WHEN ALL OF SUDDEN IT CAUGHT ON FIRE. TOOK VEHICLE TO DEALER FOR A CHECK UP, BUT THE CAUSE WAS UNDETERMINED AT THIS TIME, HOWEVER, IT SEEMED TO BE A SIMILAR PROBLEM TO AN ELECTRICAL SHORT WITHIN THE CRUISE CONTROL SWITCH.*AK
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10119139April 25, 2005ELECTRICAL SYSTEM
1999 FORD F250 EXPERIENCED PROBLEMS WITH THE CIGARETTE LIGHTER.*MR WHEN THE LIGHTER WAS HOT IT WOULD POP OUT OF IT'S CHAMBER AND ONTO THE FLOOR OF THE VEHICLE. THE CONSUMER WAS CONCERNED THAT A FIRE WOULD OCCUR. THE DEALER WAS ABLE TO FIX THE PROBLEM. *NM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10118320April 23, 2005ENGINE AND ENGINE COOLING:ENGINE:GASOLINE
THE CYLINDER HEAD IN MY 2001 FORD F-250 SUPER DUTY TRUCK BLEW OUT A SPARK PLUG. THE DEALER HAS QUOTED A $3,000 REPAIR. THE REPAIR REQUIRES REPLACEMENT OF THE DRIVERS SIDE CYLINDER HEAD. RESEARCH OF THIS PROBLEM INDICATES THAT FORD HAS BEEN HAVING PROBLEMS WITH CYLINDER HEAD FAILURES IN THE 5.4 LITER TRITON V-8 MOTOR. THE APPARENT CAUSE IS DUE TO THE NUMBER OF SCREW THREADS AVAILABLE TO CONTAIN THE SPARK PLUG. THIS CYLINDER HEAD SPARK PLUG PORTS HAVE 4 TO FIVE THREADS AVAILABLE TO ENGAGE THE PLUG, WHICH IS ABOUT HALF OF WHAT ONE WOULD NORMALLY EXPECT TO FIND. SPARK PLUGS BLOWING OUT OF A CYLINDER HEAD ARE RARE OR SO I THOUGHT. THERE ARE NUMEROUS POSTS ON LINE OF PEOPLE WHO HAVE HAD THE SAME THING HAPPEN, ON VARIOUS FORD PRODUCTS WHICH USE THE TRITON V-8 MOTOR. THE MILEAGE AT WHICH FAILURE OCCURS IS VARIED. THE DEALER INFORMS ME THAT I HAVE NO RECOURSE WITH FORD, SINCE MY VEHICLE IS OUT OF WARRANTY. *JB
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10118221April 21, 2005ELECTRICAL SYSTEM
2001 F250 REGULAR CAB PICKUP [XXX] THE PICKUP WAS PARKED AND CAUGHT ON FIRE. THE FIRE DEPARTMENT SURMISED THAT THE FIRE STARTED IN THE STEERING COLUMN UNDERNEATH THE DASH. THE PICKUP WAS TOTALED IN THE FIRE. *NM *JS INFORMATION REDACTED PURSUANT TO THE FREEDOM OF INFORMATION ACT (FOIA), 5 U.S.C. 552(B)(6)
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10119015April 21, 2005ELECTRICAL SYSTEM
THE VEHICLE WAS PARKED FOR TWENTY MINUTES. THERE WAS A LOUD NOISE, THE CONSUMER WENT TO SEE WHAT CAUSED THE NOISE, AND DISCOVERED, THE VEHICLE ENGINE WAS ON FIRE. THE FIRE DEPARTMENT RESPONDED TO PUT THE FIRE OUT. *NM
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10118173April 20, 2005ELECTRICAL SYSTEM:WIRING:FUSES AND CIRCUIT BREAKERS
2000F-250 SUPER-CREW HEAVY DUTY P/U CAUGHT ON FIRE AND BURNED UP THE WIRING AND FUSE PANEL ALONG WITH THE MASTER CYLINDER COVER. FORD HAS NOT RETURNED MY PHONE CALLS. FORD REPRESENTATIVE SAID IT WOULD BE 5 BUSINESS DAYS BEFORE ANYONE CALLED, IT WAS THE SECOND WEEK AND NO CONTACT WAS MADE. *AK
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10118987April 20, 2005VEHICLE SPEED CONTROL:CRUISE CONTROL
AFTER DRIVING THE VEHICLE CONSUMER WENT HOME, PARKED THE VEHICLE FOR A COUPLE OF HOURS. AFTER RETURNING TO THE VEHICLE,HE SMELLED SMOKE, LIFTED THE HOOD, AND DISCOVERED THAT CRUISE CONTROL WAS SMOKING. HE DISCONNECTED THE BATTERY, AND THE SMOKING CEASED. THE CRUISE CONTROL WAS LATER REPLACED. *AK
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10118081April 19, 2005ENGINE AND ENGINE COOLING:ENGINE:DIESEL
I GET EXHAUST FUMES / DIESEL SMELL THROUGH MY VENTS. I BROUGHT THE TRUCK IN AT 1500 MILES AND THEY REPLACED THE EXHAUST MANIFOLD. IT DIDN'T HELP. THEY SAID DRIVE IT, AND SEE IF IT GETS BETTER. I HAVE BROUGHT THE TRUCK IN 5 TIMES FOR THE SMELL, AND THEY CAN NOT FIX THE PROBLEM. FORD IS TELLING ME IT'S NORMAL. I HAVE FRIENDS WITH THE SAME VEHICLE AND THEY DO NOT GET THE FUMES COMING THROUGH THEIR VENTS. SOMETIMES THE FUMES ARE SO STRONG THAT MY EYES BURN. MY SON WILL SAY OPEN THE WINDOWS BECAUSE HIS EYES BURN FROM THE FUMES.*AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 4
- Deaths:
- 0
- #10118025April 18, 2005ENGINE AND ENGINE COOLING:COOLING SYSTEM
AT ONSET OF COLD WEATHER,(BELOW 40F), LOUD TAPPING FROM ENGINE AT IDLE AND AGAIN AT 200 RPMS. THIS LASTS UNTIL ENGINE IS WARMED UP COMPLETELY. FORD SAYS PISTON SLAP AND IT IS NORMAL. TRUCK HAS 20K MILES. UNLESS STANDARD ENGINEERING PRACTICE HAS BEEN REPEALED, PISTON SLAP IS NOT NORMAL UNDER ANY CIRCUMSTANCE. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10113347April 18, 2005ENGINE AND ENGINE COOLING:EXHAUST SYSTEM:MANIFOLD/HEADER/MUFFLER/TAIL PIPE
THE EXHAUST MANIFOLD HAD A BROKEN BOLT WHICH CAUSED FUMES TO ENTER INTO THE VEHICLE. CONSUMER HAS NOT BEEN INVOLVED IN ANY ACCIDENT TO CAUSE THE BOLT TO BREAK.*AK EXHAUST MANIFOLD WARPED CAUSING AN EXHAUST LEAK WHICH RESULTED IN ALL EXHAUST TO ENTER THE VEHICLE'S CAB. *BF *NM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10117941April 15, 2005VEHICLE SPEED CONTROL:ACCELERATOR PEDAL
UNINTENDED ACCELERATION,TRUCK ACCELERATES WITHOUT DRIVER'S INPUT FOR SEVERAL SECONDS.VERY DANGEROUS.WAS VERIFIED AT THE DEALER. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10116910April 14, 2005FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
FUEL FLOWING FROM FUEL TANK FILLER CAP. 1994 FORD F-250 WITH DUAL FUEL TANKS HAS CONDITION WHICH OVERFILLS TANK AND CAUSES STEADY FUEL FLOW FROM FILLER CAP. CORRECTIVE ACTION REQUIRED REPLACING BOTH FUEL PUMP ASSEMBLIES. THERE ARE MULTIPLE COMPLAINTS OF THIS CONDITION IN THIS DATABASE, UNFORTUNATELY THEY ARE SPREAD THROUGH VARYING CATEGORIES. MANUFACTURER WARRANTED SAME CONDITION FOR PREVIOUS MODEL YEAR (1993) BUT WAS UNRESPONSIVE TO INQUIRIES REGARDING 1994 MODEL YEAR.*AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0