Ford F-150 Complaints (1993)
586 consumer complaints on file.
- #10213453January 2, 2008VEHICLE SPEED CONTROL:CRUISE CONTROL
TL*THE CONTACT OWNS A 1993 FORD F150. THE CONTACT RECEIVED A RECALL NOTICE IN AUGUST OF 2007 FOR THE VEHICLE SPEED CONTROL: CRUISE CONTROL. HE TOOK THE VEHICLE TO THE DEALER TO HAVE THE DEACTIVATION SWITCH DISCONNECTED AND THEY STATED THAT THEY DID NOT KNOW WHEN FORD WOULD RELEASE THE PARTS TO HAVE THE RECALL COMPLETED. AS OF JANUARY 2, 2008, THE PARTS ARE STILL UNAVAILABLE. THERE HAD BEEN NO FAILURE TO DATE. THE CURRENT MILEAGE WAS 109,000.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10211858December 13, 2007VEHICLE SPEED CONTROL
RECALL LETTER DATED AUGUST 2007 (RECALL 05S28) SAID SCDS POSES SAFETY HAZARD; SAID DEALER WILL REPLACE FREE OF ALL CHARGES. I CONTACTED THE DEALER WHO SAID PARTS UNAVAILABLE FOR TWO MONTHS. I CHECKED BACK IN MID-OCTOBER; WAS TOLD TO CALL BACK IN MID=DECEMBER. TODAY (12/13) I WAS TOLD TO CALL BACK IN JANUARY! WHAT'S UP? *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10210050November 27, 2007VEHICLE SPEED CONTROL
TL*THE CONTACT OWNS A 1993 FORD F150. THE CONTACT RECEIVED A SAFETY RECALL NOTICE IN AUGUST FOR NHTSA CAMPAIGN ID NUMBER 07V336000 (VEHICLE SPEED CONTROL). HE WAS INFORMED THAT THE PART WOULD BE UNAVAILABLE UNTIL JANUARY OF 2008. THERE HAD BEEN NO FAILURE TO DATE. THE PURCHASE DATE WAS UNKNOWN. THE CURRENT MILEAGE WAS 185,000.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10209521November 20, 2007FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
TL*THE CONTACT OWNS A 1993 FORD F150. WHILE DRIVING AT ANY SPEED AND USING THE RESERVE FUEL TANK, THE FUEL WOULD TRANSFER TO THE MAIN TANK. THIS CAUSED GASOLINE TO OVERFLOW PAST THE FILLER CAP. AS OF NOVEMBER 20, 2007, THE DEALER HAD NOT INSPECTED THE VEHICLE. THE DEALER STATED THAT HER VIN WAS INCLUDED IN NHTSA CAMPAIGN ID NUMBER 00V424000 (FUEL SYSTEM, GASOLINE: STORAGE: TANK ASSEMBLY). THE FAILURE MILEAGE WAS 140,000 AND CURRENT MILEAGE WAS 145,000.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10208559November 9, 2007FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
TL*THE CONTACT OWNS A 1993 FORD F150. THE CONTACT RECEIVED A RECALL NOTICE, BUT NEVER TOOK THE VEHICLE TO GET REPAIRED. THE DEALER STATED THAT THE RECALL WAS OUTDATED AND THEY WOULD NOT PERFORM THE REPAIR. THE FAILURE IS A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY THAT CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO RETURN TO THE SECOND TANK. AS A RESULT, THE CAPACITY OF THE SECOND TANK BECOMES TOO GREAT AND CREATES FUEL SPILLAGE. THE VEHICLE IS CURRENTLY PARKED AT HIS HOME. THE RECALL NUMBER WAS UNAVAILABLE. THE CURRENT AND FAILURE MILEAGES WERE 150,000.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10206338October 19, 2007VEHICLE SPEED CONTROL
TL*THE CONTACT OWNS A 1993 FORD F150. THE CONTACT RECEIVED A SAFETY RECALL NOTICE FOR NHTSA CAMPAIGN ID NUMBER 07V336000 (VEHICLE SPEED CONTROL) IN AUGUST OF 2007. HE CALLED THE SHOP FOREMAN AND WAS INFORMED THAT THE PARTS WERE UNAVAILABLE. HE CALLED THE DEALER AGAIN ON OCTOBER 19, 2007 AND WAS INFORMED THAT THEY STILL DID NOT HAVE THE PARTS AND PROBABLY WOULD NOT RECEIVE ANY UNTIL NOVEMBER. THE SHOP FOREMAN STATED THAT THE SHORTAGE OF PARTS WAS PROBABLY BECAUSE THEY WERE BEING PLACED ON EMERGENCY VEHICLES, SUCH AS AMBULANCES. THERE HAD BEEN NO FAILURE TO DATE. THE PURCHASE DATE WAS UNKNOWN. THE CURRENT MILEAGE WAS 120,000. UPDATED 01/02/08. *LJUPDATED 12/12/07 *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10206064October 10, 2007VEHICLE SPEED CONTROL
1993 FORD F-150 RECALL ON SPEED CONTROL SWITCH DEACTIVATION. CUSTOMER STATES THAT HE WAS TOLD THE PARTS WOULDN'T BE IN UNTIL NEXT YEAR BUT THE DEALER DID DEACTIVATE THE SWITCH. *KB *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10204986October 2, 2007VEHICLE SPEED CONTROL
1993 FORD F-150 WITH A RECALL CONCERNING THE SPEED CONTROL FUSE HARNESS. CUSTOMER STATES THAT THE DEALER MADE THE APPOINTMENT TO INSTALL THE NEW FUSE HARNESS, AND WHEN HE ARRIVED THEY TOLD HIM THEY WERE OUT AND WOULD HAVE TO WAIT. *KB *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10202223September 7, 2007ELECTRICAL SYSTEM
1993 FORD F- 150,CAUGHT FIRE,AND BURNED TO GROUND,TOTAL LOSS. *JB
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10202113September 6, 2007VEHICLE SPEED CONTROL
TL*THE CONTACT OWNS A 1993 FORD F150. THE CONTACT STATED THAT THE CRUISE CONTROL WAS DIFFICULT TO ENGAGE WHILE DRIVING 70 MPH OR GREATER. THE CRUISE CONTROL BUTTON HAD TO BE PRESSED REPEATEDLY FOR IT TO ENGAGE. THE CURRENT MILEAGE WAS 191,000 AND FAILURE MILEAGE WAS 140,000.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10201341August 31, 2007FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
TL*THE CONTACT OWNS A 1993 FORD F150. THE CONTACT STATED THAT THE FUEL FROM THE RESERVE TANK ENTERED THE MAIN TANK WITHOUT WARNING. THERE IS A RECALL FOR THE FUEL TANK STORAGE ASSEMBLY (NHTSA CAMPAIGN ID NUMBER 00V424000). THE DEALER REPAIRED THE FAILURE AS PART OF THE RECALL, HOWEVER, THE FAILURE CONTINUED TO OCCUR. THE DEALER REFUSED TO MAKE ANOTHER REPAIR BECAUSE THEY ALREADY REPAIRED THE RECALL. THE FAILURE MILEAGE WAS 46,000 AND CURRENT MILEAGE WAS 57,000.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10198966August 9, 2007VEHICLE SPEED CONTROL:ACCELERATOR PEDAL
TL*THE CONTACT OWNS A 1993 FORD F150. THE CONTACT STATED THAT UPON ACCELERATION OF THE VEHICLE, THE VEHICLE WOULD TAKE OFF SUDDENLY, WITH NO WARNING. THE VEHICLE WAS PUT IN NEUTRAL UNTIL THE VEHICLE RETURNED TO NORMAL. THE MECHANIC STATED THERE WAS NO FAILURE. THE CURRENT MILEAGE WAS 58,000. THE FAILURE MILEAGE WAS UNKNOWN.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10191059May 17, 2007FUEL SYSTEM, GASOLINE
TL*THE CONTACT OWNS A 1993 FORD F150. THE VEHICLE IS EQUIPPED WITH A DUAL FUEL TANK, BUT ONLY ONE IS ACCEPTING FUEL. THE FAILURE IS CAUSING FUEL TO SPILL. THE CONTACT REFERENCED RECALL # 01I008000 (FUEL SYSTEM, GASOLINE). THE CURRENT MILEAGE IS 156,000 AND FAILURE MILEAGE WAS 148,000. THE CONSUMER STATED BOTH TANKS TAKE FUEL, THERE IS A CROSS FLOW CONDITION. THE FAILURE IS CAUSING FUEL TO SPILL THROUGH THE FILLER CAP. UPDATED 07/06/07 *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10189741May 4, 2007FUEL SYSTEM, GASOLINE
(1) FILLED FUEL TANKS WITH GAS (2) FUEL BEGAN PUSHING OUT OF THE REAR FILLER CAP AFTER A FEW MINUTES OF DRIVING. NOTIFIED BY ANOTHER DRIVER AND PULLED OVER. OPENED THE FUEL DOOR COVER AND SAW GAS SPILLING OUT AROUND THE CAP. TOOK THE CAP OFF AND FUEL BLEW OUT AT ME. MYSELF AND MY DAUGHTER HAD GASOLINE ALL OVER US. (3) TOOK IT TO THE DEALER AND WAS INFORMED IT WAS A KNOWN DEFECT AND THE RECALLED PART HAD BEEN REPLACED WITH REDESIGNED FUEL PUMP IN 2001. NEW REDESIGN IS NOW DOING THE SAME THING. CONTACTED FORD CUSTOMER SERVICE MAY 3, 2007, WAS TOLD INITIALLY BY 'SUE' THAT FORD WOULD PARTICIPATE AND REPAIR THE VEHICLE. THEN A SUPERVISOR, ID# 1157 (SHIRA) THAT IT WAS ALREADY FIXED 28 DEC 01 AND THEY WON'T FIX IT AGAIN ALTHOUGH IT'S A KNOWN PROBLEM. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 2
- Deaths:
- 0
- #10178062January 8, 2007VEHICLE SPEED CONTROL
I WAS DRIVING NORTH (ON CRUISE CONTROL APPROX. 55 MPH) ON I 75 NEAR MILE MARKER 78 WHEN MY 1993 FORD F150 STARTING SMOKING UNDER THE HOOD. I PULLED OVER AND OPENED THE HOOD AND SAW THE ENGINE IN FLAMES. I HAD A FIRE EXTINGUISHER IN THE CAB SO I USED IT TO PUT OUT THE FIRE. THERE WAS ALSO A TRAIL OF FIRE UNDER THE TRUCK THAT A GOOD SAMARITAN EXTINGUISED AFTER HE STOPPED TO HELP. I CALLED AAA TO TOW MY TRUCK TO A LOCAL FIRESTONE SERVICE CENTER FOR REPAIRS. I BOUGHT THIS VEHICLE NEW IN 1993 AND NEVER HAD ANY RECALL ON IT. I FOUND OUT TODAY FROM MY INSURANCE COMPANY THAT THERE IS A DEFECT W/ THE CRUISE CONTROL SWITCH ON THIS MODEL FORD TRUCK. *JB
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #10160851June 27, 2006FUEL SYSTEM, GASOLINE
DT*: THE CONTACT STATED THERE ARE PROBLEMS WITH VEHICLE'S FUEL INTAKE. EVERY TIME FUEL WAS INJECTED INTO THE VEHICLE THE FILLER CAP WOULD OVERFLOW. THE DEALER WAS CONTACTED AND DETERMINED THAT THE VEHICLE HAD THE SAME CHARACTERISTICS OF A RECALL. THE CAPACITY OF THE RECEIVING TANK EXCEEDED INTAKE AND CAUSED AN OVERFLOW FROM FILLER CAP. THE FUEL SEEPING COULD RESULT IN FIRE. HOWEVER THE VIN WAS NOT INCLUDED IN THE RECALL. THEREFORE ANY SERVICE WOULD INCUR A CHARGE.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10160732June 26, 2006FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
DT*: THE CONTACT STATED THAT WHILE DRIVING AT 45 MPH, THERE WAS AN ODOR OF GASOLINE COMING FROM THE VEHICLE. THE CONTACT WAS MOTIONED TO PULL OVER BY ANOTHER MOTORIST, AND WHEN THE CONTACT EXITED THE VEHICLE AND EXAMINED BOTH TANKS, THE FRONT TANK WAS OVERFLOWING GASOLINE. THE VEHICLE WAS EXAMINED BY AN INDEPENDENT REPAIR SHOP, WHERE IT WAS DETERMINED THAT THERE WAS A PROBLEM WITH THE FUEL REGULATOR. THERE IS A NHTSA RECALL # 93V125000. THE VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO THE VIN.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10156436April 29, 2006FUEL SYSTEM, GASOLINE:STORAGE
1. ONE MORNING I STARTED MY VEHICLE AND IT WOULD NOT START ON THE FRONT TANK SO I BEGAN TO USE THE REAR TANK ONLY. 2. VERY SOON THEREAFTER, GASOLINE BEGAN POURING OUT OF THE FRONT TANK FILLER CAP. IT'S TOO DANGEROUS TO DRIVE, WHATEVER GAS GETS PUT INTO THE REAR TANK IS PUMPED INTO THE FRONT TANK WHILE BEING DRIVEN AND GAS SPILLS OUT OF CAP GOING DOWN THE ROAD. 3. NOTHING HAS BEEN CORRECTED YET, I'M TRYING TO GET LOCAL FORD DEALER TO FIX IT BUT THEY SAY THERE IS NO RECALL FOR MY VIN. *JB
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10155868April 22, 2006FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
I HAVE FOUND A PROBLEM WITH MY VEHICLE WHICH IS, ACCORDING TO NHTSA CAMPAIGN NUMBER 93V125000, RECALLED FOR A SAFETY PURPOSE. A MALFUNCTIONING CHECK VALVE IN THE FUEL PUMP ASSEMBLY CAUSES FUEL TO RETURN TO THE SECOND TANK AND OVERFLOW. THERE IS A GREAT CHANCE FOR A FIRE BECAUSE OF THE FUEL OVERAGE. HOWEVER, FORD DOES NOT RECOGNIZE THIS AS A RECALL ON MY VEHICLE, BASED SOLELY ON MY VEHICLE IDENTIFICATION NUMBER. *JB
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10150786February 21, 2006FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP
A FUEL SYSTEM PARTS FAILURE RESULTED IN THE TRANSFER OF GASOLINE FROM ONE TANK TO THE OTHER. I BECAME AWARE OF THE PROBLEM WHEN I SAW FUEL RUNNING ONTO THE PAVEMENT UNDER THE VEHICLE. *NM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0