2018-2021 Audi 48V System Warning DTC P0CA700 U046900
Owners of 2018-2021 Audi models may experience a 48V electrical system warning, no-start, or stalling, often accompanied by DTC P0CA700 or U046900. Audi Technical Service Bulletin 2058831/4 addresses these issues with a software update for the starter/generator control module or, in some cases, a…

También aplica a
- Audi A6
- 2021
- Audi A6 allroad
- 2021
- Audi A7
- 2021
- Audi A7 e
- 2021
- Audi A8 L e
- 2021
- Audi R8
- 2021
- Audi RS 6 Avant
- 2021
- Audi RS Q8
- 2021
- Audi S6
- 2021
- Audi S7
- 2021
- Audi S8
- 2021
- Audi SQ7
- 2021
- Audi SQ8
- 2021
▸ Mostrar 7 más▾ Mostrar menos
Owners of 2018-2021 Audi models may experience an Audi 48V system warning in the instrument cluster. This warning can be intermittent and may be accompanied by other significant issues. This Technical Service Bulletin (TSB) 2058831/4, issued on March 2, 2022, addresses these concerns. It supersedes a previous bulletin, Group 27 number 21-40, dated December 6, 2021.
Revision History
This bulletin has undergone several revisions to refine its guidance:
- Revision 4: Updated the labor operation details within the warranty section.
- Revision 3 (December 6, 2021): Revised the condition description to include additional customer statements, expanded the technical background information, updated the service procedure with a new photo and steps 1-2, and revised the warranty labor operation.
- Revision 2 (April 1, 2021): Updated the header to include Model Year 2021 vehicles.
Symptoms
Owners might notice an intermittent "Intermittently a warning for the 48V vehicle electrical system is displayed in the instrument cluster." Additionally, customers may report one or more of the following conditions:
- "The vehicle does not start."
- "The vehicle stalled."
- "The battery is dead."
Fault Codes / DTCs
Workshop findings indicate that one or more of the following Diagnostic Trouble Codes (DTCs) may be stored in the vehicle's control modules:
| Code | Description | Module |
|---|---|---|
| P0CA700 | Hybrid battery discharge current too high static or sporadic | Battery management 2 (Battery 48V) control module, J1120 (address word 0021) |
| U046900 | Invalid data received from starter/generator control module | ECM, J623 (address word 0001) |
Technical Background
The root cause of the Audi 48V system warning and related issues is often a software discrepancy in the starter/generator control module, C29 (address word 00CC). If the 48V vehicle electrical system warning displayed in the instrument cluster is ignored, the 12V system may drain. This can lead to critical vehicle conditions such as a vehicle stall or a no-start situation.
Diagnosis / Trigger Conditions
For vehicles presenting with DTC U046900 in the Engine Control Module (ECM), J623, technicians should check the expanded ambient conditions of this DTC. Specifically, they need to look for the value of "Starter generator, actual mode 48V".
Figure 1 in the bulletin illustrates a DTC U046900 entry with an expanded ambient condition showing the "Starter generator, actual mode 48V" value as '5' in the ECM, J623. If this value is '5', the starter/generator should be replaced. If no value is displayed, an ODIS feedback should be submitted.
Repair Procedure Summary
The primary solution involves updating the software of the starter/generator control module, C29. This procedure requires following the instructions outlined in TSB 2011732: 00 Software Version Management (SVM), operating instructions.
Technicians will update the starter/generator control module, C29 (address word 00CC), using the SVM action code listed below:
| Model | Old Hardware Part Number | Old Hardware Version | Old Software Part Number | Old Software Version | New Software Version | SVM Code Input |
|---|---|---|---|---|---|---|
| A6, A7, Q7, Q8 | 4N0903028 | H17 | 4N0903028 | 523 | 527 | CCA001 |
If the diagnostic step for DTC U046900 indicates a "Starter generator, actual mode 48V" value of 5, the starter-alternator must be replaced instead of just a software update.
Warranty Information
Repairs for this issue are covered under specific warranty conditions:
- Claim Type 110: For vehicles up to 48 months or 50,000 miles.
- Claim Type G10: For Audi Certified Pre-Owned (CPO) vehicles, requiring owner verification.
Important Warning: If your vehicle falls outside of these warranty periods, this Technical Service Bulletin is for informational purposes only, meaning the repair cost may not be covered.
The service number for this bulletin is 2726, with a damage code of 0040. Labor operations include:
- Software Update (Includes checking for DTCs): Operation code 0151 0000, with time stated on the diagnostic protocol (maximum 100 Time Units). This is only performed if an update is required.
- Replace starter-alternator: Operation code 2726 XXXX, applicable only if the expanded ambient condition "Starter generator, actual mode 48V" value is 5. Refer to the Service Repair Time (SRT) for associated operations.
- Diagnostic Time (GFF): Operation code 0150 0000, only if a part is replaced, with time stated on the diagnostic protocol (maximum 100 Time Units).
Road tests performed prior to the service procedure are not covered and have no allowance (0 TU).
Additional Information
To complete this procedure, technicians will also need to refer to TSB 2011732: 00 Software Version Management (SVM), operating instructions. All part and service references provided in this TSB 2058831/4 are subject to change. Always consult your Parts Department and/or ETKA for the latest information and parts bulletins. The Repair Manual should also be checked for any fasteners, bolts, nuts, and screws that require replacement during the repair.
NHTSA ID: 10208897
Frequently Asked Questions
- What does the Audi 48V system warning mean?
- The Audi 48V system warning indicates an issue with the vehicle's 48-volt electrical system, which can lead to problems like the vehicle not starting, stalling, or a dead battery. It is often associated with DTCs P0CA700 or U046900.
- What are the common DTCs associated with the Audi 48V system warning?
- The primary Diagnostic Trouble Codes (DTCs) linked to the Audi 48V system warning are P0CA700 (hybrid battery discharge current too high) found in the Battery management 2 control module (J1120), and U046900 (invalid data received from starter/generator control module) found in the ECM (J623).
- How is the Audi 48V system warning issue resolved?
- According to TSB 2058831/4, the issue is typically resolved by performing a software update on the starter/generator control module (C29) using SVM action code CCA001. In specific cases where the 'Starter generator, actual mode 48V' value is 5, the starter/generator may need to be replaced.
- Is the repair for the Audi 48V system warning covered by warranty?
- Yes, the repair is covered under warranty for up to 48 months or 50,000 miles, whichever comes first, under Claim Type 110. It is also covered for CPO (Certified Pre-Owned) vehicles under Claim Type G10. If the vehicle is outside these warranty periods, the Technical Service Bulletin serves as informational guidance.
- What happens if the 48V system warning is ignored?
- If the 48V vehicle electrical system warning is ignored, the 12V system may drain, potentially leading to the vehicle stalling or a complete no-start condition.
Otras revisiones de este TSB
- 2024-2026 Audi Q8 48V Starter Generator DTCs P0A1A00 P19F800U046900
- 2024-2026 Audi 48V Starter Generator DTCs P0A1A00 P19F800U046900
- 2024-2025 Audi Q7 Q8 Starter Generator DTCs P0A1A00 P19F800U046900
- 2021-2023 Audi 48V Electrical System Warning U046900 TSBU046900
- 2021-2023 Audi MHEV Electrical System Fault TSB 2073284/4U046900
- 2024-2025 Audi Q7 / Q8 48V Starter Generator DTCs P0A1A00 P19F800U046900
- 2021-2023 Audi 48V Electrical System Malfunction TSB 2058831/15U046900
- 2019-2025 Audi MHEV Electrical System Fault TSBU046900
Related Articles
2021-2025 Audi Engine Control Module Software Update 53ZC
Audi has issued an update to its Engine Control Module (ECM) software campaign 53ZC / WARR EXT – U82, dated March 20, 2026. This dealer communication indicates that additional vehicles have been added to the affected chart for this important software update. Owners of 2021-2025 Audi Q8, A7, A6…
2021-2025 Audi Fuel System DTCs P014800 and P008700
Audi Technical Service Bulletin (TSB) 2079461/3 details diagnostic and repair procedures for 2021-2025 Audi vehicles experiencing a 'MIL light on' or 'limp-home function' due to fuel system DTCs P014800 or P008700. This bulletin guides technicians on diagnosing and potentially replacing the…
2021-2025 Audi Black Trim Discoloration TSB
Audi has issued Technical Service Bulletin 2078651/4 to address red, purple, gray, or metallic discoloration on black exterior trim strips in 2021-2025 Audi models. This TSB explains the cause (paint UV resistance issue) and outlines the replacement procedure for affected components.
2021 Audi Virtual Cockpit Display Fault TSB 2078439/2
Audi TSB 2078439/2 addresses issues with the virtual cockpit display in 2021 A6, A7, A8, Q7, Q8 models, including a black screen or "Instrument cluster: fault" message, often accompanied by DTC B200049.
2021-2026 Audi TFSI Engine Oil Leak TSB 2053278/10
Audi has released Technical Service Bulletin 2053278/10 to address oil leaks from the cylinder head on 2.9 and 3.0 TFSI engines in various 2021-2026 models. Learn about symptoms, diagnosis, and the recommended repair process.
Leave a comment
Comments are moderated and may take a moment to appear. Only your first name and the initial of your last name are shown publicly.
Comments