BMW R 1200 RT Complaints
270 consumer complaints on file.
- #10487624December 7, 2012FUEL/PROPULSION SYSTEM
I STARTED THE MOTORCYCLE ENGINE. A FEW SECONDS AFTER IT STARTED, GASOLINE STARTED TO GUSH FROM THE FRONT OF THE BIKE ONTO THE ENGINE. BEFORE I KNEW IT, I WAS IN A PUDDLE OF GASOLINE. I SHUT IT OFF AS SOON AS I REALIZED WHAT WAS HAPPENING. I MOPPED UP THE GASOLINE OFF OF THE FLOOR TO ELIMINATE THE FIRE DANGER. I LOCKED THE STEERING AND PUT THE KEY AWAY AFTER THAT. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485882November 23, 2012FUEL/PROPULSION SYSTEM
THE FUEL PUMP CRACKED AROUND THE POINT WHERE THE FUEL LINE CONNECTS TO THE FLANGE THAT MOUNTS THE FUEL PUMP TO THE TANK. THESE CRACKS ALLOWED FUEL TO LEAK DOWN THE SIDE OF THE MOTORCYCLE AND ONTO MY CLOTHING AND THE FAIRING OF THE MOTORCYCLE. IT WAS NOT NOTICED UNTIL THE MOTORCYCLE WAS STOPPED. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485789November 22, 2012FUEL/PROPULSION SYSTEM
TRAVELING ON I-44 EAST OF JOPLIN MO. SIGNIFICANT ODOR OF GASOLINE. FOUND A SAFE PLACE TO PULL OFF HIGHWAY AND SAW FUEL DRIPPING FROM UNDER THE LEFT FAIRING PANEL. REMOVED THE PANEL TO FIND PUDDLES OF GAS IN THE FAIRING RECESS AND THE FUEL PUMP RECESS. WIPED IT ALL UP AND TURNED ON THE KEY, WHICH STARTED THE PUMP AND A STRONG STREAM OF FUEL WAS PUMPED OUT FROM A SERIOUS CRACK IN THE FUEL PUMP PLATE AT THE FUEL LINE FITTING. THE MOTORCYCLE WAS UNSAFE TO RIDE SO I CALLED FOR A TRAILER, TRAILERED THE BIKE TO KANSAS CITY, MO AND ENGLE MOTORS. THE ENTIRE FUEL PUMP ASSY HAD TO BE REPLACED AT A COST OF $621.52. THERE IS NO QUESTION I WAS VERY LUCKY THE MOTORCYCLE DIDN'T CATCH FIRE WHILE I WAS RIDING IT. I CALLED AND FILED A COMPLAINT TO BMW WITH NO RESPONSE. I HAVE RECEIPTS TO PROVE THE FAILURE AND WITNESSES. BMW NEEDS TO OWN THIS FAILURE AND RECALL ALL THESE MACHINES TO INSURE NO ONE DIES AS A RESULT OF THIS. CALLING THIS A FIRE HAZARD IS UNDERSTATING THE PROBLEM. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485796November 22, 2012FUEL/PROPULSION SYSTEM
A FUEL LEAK DEVELOPED IN THE PLASTIC FUEL PUMP FLANGE AT THE FUEL LINE QUICK DISCONNECT FITTING. I SMELLED A STRONG GASOLINE SMELL IN MY GARAGE WHERE MY NATURAL GAS WATER HEATER IS LOCATED. HAVING HEARD OF THIS COMMON PROBLEM ON BMW SPORT TOURING FORUM, I REPAIRED CRACKS IN THAT FLANGE WITH JB WELD AND A $30 CLAMP MADE JUST TO FIX THIS PROBLEM AVAILABLE ONLINE. I AM REPORTING THIS NOW TO ADD MY INCIDENT TO YOUR DATABASE ON THIS ISSUE. IF MY GARAGE HAD BEEN SMALLER OR THE LEAK A LITTLE WORSE, IT COULD HAVE BEEN A DISASTER. *TR ## VIN FAILED
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485368November 21, 2012FUEL/PROPULSION SYSTEM
THE FUEL LEVEL SENSOR HAS FAILED (TWICE) AND HAS BEEN REPLACED BY THE BMW MOTORCYCLE DEALERSHIP. THE LATEST FUEL LEVEL SENSOR IS NOT WORKING PROPERLY EITHER AND WILL EVENTUALLY BE REPLACED AGAIN BEFORE THE WARRANTY EXPIRES IN FEB 2013. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485376November 21, 2012FUEL/PROPULSION SYSTEM
I DISCOVERED THAT MY FUEL PUMP WAS DEVELOPING CRACKS AROUND THE FUEL LINE FITTING. I DISCOVERED THE CRACKS BEFORE COMPLETE FAILURE OCCURRED. I DID NOT SUFFER A FAILURE ONLY BECAUSE I HAD LEARNED OF THIS POTENTIAL SAFETY HAZARD FROM FRIENDS, ONE OF WHOM HAD HIS LEFT LEG SOAKED WITH GASOLINE AS A RESULT OF GASOLINE SPRAY COMING FROM BENEATH THE LEFT SIDE BODY PANELS. MY FRIEND, A MECHANICAL ENGINEER, ADVISED THAT BMW USED PIPE THREADS IN THE FITTING THAT RESULTED IN OUTWARD FORCE UPON TIGHTENING, AND FAILURE WOULD LIKELY OCCUR ON ALL MODELS. I PURCHASED A "FIX" KIT FOR THIS WIDELY KNOWN PROBLEM FROM BEEMER BONEYARD, NAMELY A METAL CLAMP TO PLACE AROUND THE BASE OF THE PLASTIC FUEL PUMP FITTING. I HOPE IT HOLDS THE CRACKS FROM GROWING ANY WORSE. THIS FUEL PUMP SHOULD BE RECALLED. I UNDERSTAND THAT THERE IS AN OPEN INVESTIGATION ON THIS ISSUE. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485276November 20, 2012FUEL/PROPULSION SYSTEM
TL* THE CONTACT OWNS 2007 BMW R1200RT MOTORCYCLE. THE CONTACT STATED THERE WAS A CRACK IN THE FUEL PUMP CAUSING THE FUEL TO LEAK. WHEN ROUTINE SERVICE WAS DONE ON THE VEHICLE WHEN THE MECHANIC NOTICED THE FUEL LEAK. THE MECHANIC STATED THAT THE FUEL PUMP NEEDED TO BE REPLACED. THE MANUFACTURER WAS NOT NOTIFIED. THE FAILURE MILEAGE WAS 98,077.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485317November 20, 2012ELECTRICAL SYSTEM, FUEL/PROPULSION SYSTEM
THE DIGITAL STRIP FUEL GAUGE SIMPLY FROZE IN THE FULL POSITION, IT NO LONGER REGISTERS NOR DOES THE MILES REMAINING DIGITAL READOUT. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485337November 20, 2012FUEL/PROPULSION SYSTEM
MOTORCYCLE DEVELOPED SEVERE FUEL LEAK AT THE FLANGE ON THE FUEL TANK WHERE THE FUEL LINE CONNECTS. SEVERAL CRACKS IN THE FLANGE ALLOWED FUEL TO LEAK OUT AND LAND ON ENGINE AND EXHAUST. MAJOR FIRE HAZARD!!! *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485348November 20, 2012FUEL/PROPULSION SYSTEM
DISCOVERED SEVERAL CRACKS AT FUEL PUMP OUTLET FLANGE. REPAIRED AT MY OWN COST IN ORDER TO PREVENT POSSIBLE FIRE. THIS IS A WELL-KNOWN AND WELL-DOCUMENTED PROBLEM WITH THIS FUEL PUMP. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485351November 20, 2012FUEL/PROPULSION SYSTEM
AS I WAS DOING ROUTINE MAINTENANCE, I NOTICED SEVERAL SMALL CRACKS ON THE "FLANGE" WHERE THE QUICK DISCONNECT EXITS THE TANK. I USED A RING CLAMP TO CLOSE THE CRACKS. I BELIEVE THIS TO BE POTENTIALLY VERY DANGEROUS, SINCE LEAKING GASOLINE COULD EASILY RUN DOWN THE OUTSIDE OF THE TANK AND END UP ON HOT ENGINE/EXHAUST PARTS, CAUSING A FIRE... *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10485221November 19, 2012ELECTRICAL SYSTEM
THE GAS GAUGE SENSOR STRIP STOPS WORKING AND WILL READ THAT YOU HAVE MORE GAS THAN YOU ACTUALLY DO. THIS IS EXTREMELY DANGEROUS AND CAN CAUSE THE RIDER TO RUN OUT OF GAS AND BE STRANDED IN MOVING TRAFFIC. THERE ARE TOO MANY COMPLAINTS FROM BMW MOTORCYCLE OWNERS TO IGNORE THIS PROBLEM ANY LONGER! PLEASE MAKE THE MANUFACTURER ADDRESS THIS PROBLEM INSTEAD OF CONTINUING TO PROFIT OFF OF A SAFETY ISSUE. A GOOGLE SEARCH ON "BMW MOTORCYCLE FUEL STRIP" WILL GIVE YOU ALL THE LEVERAGE YOU NEED. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10483688November 8, 2012FUEL/PROPULSION SYSTEM
THIS IS THE SECOND TIME MY MOTORCYCLE RAN OUT OF FUEL EVEN THROUGH THE FUEL GAUGE WAS READING 1/4 TANK. IT OCCURRED AT HIGHWAY SPEEDS. THE ENGINE JUST STOPS RUNNING WITHOUT WARNING. THIS IS THE 4TH TIME THAT MY MOTORCYCLE FUEL SENSOR HAS FAILED. WE NEED BMW TO RECALL AND INSTALL A FLOAT SYSTEM SIMILAR TO THE NEW MODELS. BMW HAS BEEN AWARE OF THIS PROBLEM FOR YEARS AND REFUSES TO TAKE RESPONSIBILITY. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10472852August 28, 2012FUEL/PROPULSION SYSTEM
VEHICLE RAN OUT OF FUEL, WHILE FUEL INDICATOR SHOWED THERE WAS 1/4 TANK LEFT. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10472467August 25, 2012FUEL/PROPULSION SYSTEM
BIKE DIED ENTERING INTERSECTION. ONLY SPACING AVERTED ACCIDENT. BOUGHT USED LESS THAN ONE WEEK AGO. FUEL GAUGE SHOWED JUST UNDER 1/2 TANK AND 120 MILES TO EMPTY. GAS TANK WAS EMPTY WITHOUT WARNING. GAS GAUGE STRIPS IN TANK FAIL - BMW HAS KNOWN ABOUT THIS SAFETY ISSUE FOR YEARS, ARE YOU? AND, IF "GERMAN ENGINEERING" IS MORE THAN MARKETING, WHY HAVEN'T THEY FIXED IT? *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10471642August 20, 2012FUEL/PROPULSION SYSTEM
THE HIGH PRESSURE OUTLET PORT ON THE FUEL PUMP ASSEMBLY DEVELOPED CRACKS THAT EXTENDED FROM THE OUTSIDE OF THE FEMALE PORTION OF THE OUTLET INTO THE THREADS. THIS ALLOWED GASOLINE TO SPRAY ONTO THE INNER PORTION OF THE BODY MOLDING AND RAN DOWN ONTO THE ENGINE AND THE RIDERS LEG ON THE LEFT SIDE. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10471471August 19, 2012SERVICE BRAKES
ABS MODULATOR FAILED. $3500 REPAIR. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10465491July 13, 2012POWER TRAIN
DURING REAR WHEEL BRAKE REPLACEMENT, FOUND CRACK IN ONE BOLT HOLE THAT SECURES REAR WHEEL TO DRIVE FLANGE. CRACK COULD ALLOW BOLT SECURING THE REAR WHEEL TO LOOSEN WHILE DRIVING. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10464658July 9, 2012ENGINE
TL* THE CONTACT OWNS A 2012 BMW R1200RT MOTORCYCLE. THE CONTACT STATED THAT WHENEVER STOPPED AND IN FIRST GEAR, THE VEHICLE WOULD STALL. THE VEHICLE WAS ABLE TO BE RESTARTED IMMEDIATELY. THE FAILURE RECURRED AS OFTEN AS ONCE A MONTH. THE VEHICLE WAS TAKEN TO THE DEALER WHO STATED THAT THEY WOULD HAVE TO KEEP THE VEHICLE FOR INSPECTION OF THE FAILURE. THE MANUFACTURER WAS NOTIFIED WHO BUT PROVIDED NO ASSISTANCE. THE FAILURE MILEAGE WAS 25,000.
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #10464617July 8, 2012FUEL/PROPULSION SYSTEM
THIS FAILURE IS NOT LIMITED TO THE 2005 BMW R1200RT. THE SAME FUEL PUMP IS USED FROM 2005-2009 IN THE RT1200RT AND R1200GS. THE FUEL PUMP HOUSING HIGH-PRESSURE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE CRACKS UNDER HIGH PRESSURE CYCLING AND LEAKS, SENDING RAW FUEL DOWN THE LEFT FAIRING IN CLOSE PROXIMITY OF THE VEHICLES LEFT EXHAUST PIPE AND IGNITION SYSTEM COMPONENTS. THE MOTORCYCLE FAIRING EFFECTIVELY CAPTURES THE FUEL VAPORS CREATING A SIGNIFICANT RISK FOR FIRE. IN ADDITION, LEAKING FUEL, STREAMING ALONG THE LEFT FAIRING IS EXHAUSTED ON THE RIDERS LEFT LEG, CREATING SIGNIFICANT RISK FOR THE RIDER EVEN AFTER DISMOUNTING THE VEHICLE. CONSEQUENCES OF FAILURE THE COMBINATION OF HIGH FUEL PRESSURE AND NEGLIGENT DESIGN CREATE SUBSTANTIAL RISK FOR RIDERS OF THE IMPACTED VEHICLES. CONSEQUENCES OF THIS FAILURE ARE OUTLINED BELOW: 1. RIDERS BECOME FUEL SOAKED AS FUEL LEAKS DOWN THE LEFT FAIRING AND THEN IS FORCED BY FAIRING AIRFLOW DYNAMICS ON TO THE RIDERS LEFT LEG. 2. FUEL VAPORS, CAPTURED BY THE FAIRING AND HEATED BY THE EXHAUST PIPE BECOME EXTREMELY VOLATILE AND COULD LEAD TO A FIRE AND/OR EXPLOSION. 3. FUEL VAPORS RISING FROM THE FAIRING AND EXITING THE TOP OF THE FAIRING BETWEEN THE INSTRUMENT PANEL AND FUEL TANK, ARE BLOWN BY AIRFLOW INTO THE RIDERS FACE. THE CARCINOGENIC ASPECTS OF FUEL INHALATION ARE DOCUMENTED. EXAMINATION OF THE FUEL PUMP ASSEMBLY SUGGESTS THAT THE HIGH-PRESSURE FUEL QUICK DISCONNECT REINFORCEMENT FLANGE WAS INADEQUATELY DESIGNED FOR THE FUEL PUMP OUTLET PRESSURES. THE NON-METALLIC (COMPOSITE) PUMP HOUSING COMBINED WITH A COMPOSITE HIGH-PRESSURE DISCONNECT FITTING IS UNSUITED FOR THE PART. HIGH PUMP PRESSURE EXPANDS THE COMPOSITE HIGH-PRESSURE FITTING CAUSING IT TO READILY LOAD THE FUEL PUMP HIGH-PRESSURE QUICK DISCONNECT FLANGE. OVER TIME, PRESSURE CYCLING CAUSES THE QUICK DISCONNECT REINFORCEMENT FLANGE TO CRACK ALLOWING FUEL TO LEAK. *TR
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0