Ford F-150 Complaints (1992)
470 consumer complaints on file.
- #859291March 28, 2000ELECTRICAL SYSTEM:ALTERNATOR/GENERATOR/REGULATOR
WHILE DRIVING ALTERNATOR OVERHEATED, CAUSING AN UNDERHOOD FIRE. CONSUMER PUT THE FIRE OUT. DEALER HAS NOT BEEN CONTACTED. *AK
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #858734March 17, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A MALFUNCTION WITHIN THE CHECK VALVE AND THE FUEL PUMP ASSEMBLY CAUSES UNUSED FUEL TO TRANSFER FROM ONE TANK TO THE SECOND, CAUSING FUEL LEAKAGE. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #720265March 17, 2000PARKING BRAKE:CONVENTIONAL:MECHANICAL:LINKAGE AND CABLE, POWER TRAIN:AUTOMATIC TRANSMISSION
THE PARKING BRAKE EQULIZER IS A C CHANNEL THAT CONNECTS THE CABLE FROM THE PEDAL ASSEMBLY TO THE TWO CABLES GOING TO THE REAR WHEELS. I HAVE HAD TWO EQULIZERS FAIL. THE FIRST ONE AT38000 MILES. THE SECOND AT 125000 MILES OR ABOUT 80000 MILES LATER. IN BOTH CASES THE EQULIZER BROKE WHERE THE PEDAL ASSEMBLY ATTACHES TO THE EQULIZER. THE TRUCK WAS PARKED WITH THE PARKING BRAKE APPLIED AND THE TRANSMISSION IN REVERSE. THE TRUCK HAS A STANDARD TRANSMISSION. THE NEXT MORNING I FOUND THE PARKING BRAKE PEDAL WOULDN'T MOVE WHEN RELEASED. I LOOKED UNDER THE TRUCK. THE BRAKE CABLE WAS LOOSE AND LAYING ON THE GROUND.THE ONLY THING KEEPING MY TRUCK FROM ROLLING DOWN MY DRIVE WAS THE TRANSMISSION. BOTH TIMES THE EQULIZER FAILED UNDER SIMILAR CIRCUMSTANCES. THIS IS A VERY UNSAFE CONDITION. I THINK THE EQULIZER SHOULD BE MADE FROM HEAVIER STEEL TO LAST THE LIFE OF THE VEHICLE. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #720157March 15, 2000PARKING BRAKE:CONVENTIONAL:MECHANICAL:LINKAGE AND CABLE
THIS PART CONNECTS THE PARKING BRAKE PEDAL TO THE TWO CABLES THAT GO TO THE REAR WHEELS. THE BRAKE WAS APPLIED AND THEN THE PART FAILED LEAVING THE TRUCK FREE TO ROLL. THIS IS THE SECOND EQULIZER I HAVE HAD. THE FIRST ONE FAILED IN THE SAME PLACE AND THE SAME WAY. I DON'T THINK IT IS MADE OUT OF HEAVY ENOUGH STEEL. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #858345March 13, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A PORTION OF UNUSED FUEL PASSES FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, CAUSING AN OVERFLOW OF FUEL AT THE FILLER NECK. ALSO, RECALL 93V125000 DEALS WITH THE SAME PROBLEM. HOWEVER, THIS VEHICLE IS NOT INCLUDED IN THE RECALL DUE TO VIN. PLEASE PROVIDE ANY FURTHER DETAILS. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #858377March 13, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A PORTION OF UNUSED FUEL FROM ON TANK IS BEING RETURNED TO THE SECOND TANK, CAUSING FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON THE VEHICLE'S MAKE AND MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO VIN. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #858384March 13, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSES A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS, THE FRONT FILLER CAP STARTS LEAKING FUEL. CONTACTED DEALER AND MANUFACTURER.*AK *ML
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #858279March 10, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A PORTION OF UNUSED FUEL FROM ONE TANK IS BEING RETURNED TO THE SECOND TANK, RESULTING IN FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON THE VEHICLE'S MAKE AND MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED IN THE RECALL DUE TO VIN. MANUFACTURER WILL BE NOTIFIED. TRANSMISSION ALSO FAILED AT 47000 MILES AND HAD TO BE REPLACED . *AK *ML
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #858288March 10, 2000POWER TRAIN:AUTOMATIC TRANSMISSION, ELECTRICAL SYSTEM:12V/24V/48V BATTERY:CABLES
WHEN DRIVING FROM A STOPPED POSITION VEHICLE WILL SHIFT INTO NEUTRAL. COMPUTER IS RESPONSABLE FOR THIS. TO RESET THE BATTERY CABLE, IT HAS TO BE UNHOOKED. DEALER HAS BEEN CONTACTED. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #551200March 6, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
THE RECALLED CHECK VALVE FAILED CAUSES PORTIONS OF UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK, WHEN THIS OCCURS THE CAPACITY OF THE SECOND TANK IS EXCEEDED, CAUSING FUEL SPILLAGE, THE ORIGINAL RECALL DID NOT FIX THE PROBLEM. NLM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #551110February 28, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
PRIOR TO RECALL FUEL TANK FAILED(93V-125).YH
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #718534February 9, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
ON DEC. 26, 1999 IREAD IN THE HARTFORD COURANT ABOUT AN INVESTIGATION ON FORD PICK-UP TRUCKS F-150 FOR THE YEARS 1990-1993 FOR FUEL TANK LEAKAGES. IHAD TO PAY $538.55 TO HAVE ONE OF MY FUEL TANKS REPLACED DUE TO A LEAK ON 5-24-99. WHEN I CALLED FORD ON 12-27-1999 , THEY COULD NOT HELP ME, AND SAID MY VIN NUMBER WAS NOT THE NUMBERS RECALLED. I CALLED YOUR WASHINGTON PHONE NUMBER AND THE LADY TOLD ME TO FILL OUT THIS FORM ON THE INTERNET. PLEASE ADVISE ME. I BELIEVE MY TRUCK IS AMONG THE TRUCKS YOU ARE INVESTIGATING. THE FUEL TANK WAS REPLACED BY WILLIAMS FORD IN WEST HARTFORD CT. AND WE HAVE A COPY OF THE BILL IF NEEDED. PLEASE LET US KNOW THE RESULTS OF YOUR INVESTIGATION. I'M STILL SKEPITCAL IN DRIVING MY TRUCK IN FEAR THE UNREPAIRED TANK COULD LEAK. THANK YOU VERY MUCH FOR YOUR HELP WITH THIS MATTER. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #9000535February 8, 2000FUEL SYSTEM, GASOLINE
FUEL WAS RETURNING TO THE WRONG TANK, CAUSING OVERFLOW ONTO THE GROUND, REPAIRED THEN FAILED AGAIN. *MJS
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #856444February 8, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
THE FRONT TANK DRAWS FUEL FROM THE BACK TANK, WHICH OVERFLOWS THE FRONT TANK. THIS CAUSES FUEL TO SPILL ONTO THE GROUND. TRUCK WAS TAKEN TO THE DEALERSHIP. DEALER STATED THAT TRUCK WAS NOT INCLUDED IN RECALL # 93V125000 FUEL: FUEL TANK: AUXILIARY SELECTOR AND SWITCH, AND WOULD NOT BE REPAIRED FREE. PLEASE PROVIDE ANY FURTHER INFORMATION. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #855718January 28, 2000ELECTRICAL SYSTEM:IGNITION
VEHICLE WAS PARKED FOR OVER AN HOUR WHEN IT CAUGHT FIRE AROUND THE DASH OR WITHIN THE ENGINE COMPARTMENT. VEHICLE WAS TOTALED. CONTACTED FORD, BUT THEY WERE UNWILLING TO HELP PAY FOR COST OF NEW VEHICLE. *AK *ML
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #550548January 22, 2000FUEL SYSTEM, GASOLINE
GAS MOVES FROM REAR TO THE FRONT TANK DUE TO FUEL SYSTEM MALFUNCTIONING. YH
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #854238January 22, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK
EA99032, DUAL FUEL TANK CROSSFLOW/LEAKAGE; THE REAR TANK WAS REPLACED BECAUSE FUEL WAS LEAKING FROM THE BOTTOM REAR OF THE TANK. OWNER DISCOVERED FUEL LEAKAGE AFTER TRUCK WAS PARKED IN THE GARAGE OVER NIGHT. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #550445January 18, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
RECALL WORK COMPLETED ON 93V-125 (FUEL TANK ASSEMBLY), THE VEHICLE DID NOT EXPERIENCE FAILURE PRIOR TO RECALL HOWEVER AFTER REPAIR THE FAILURE WAS EXPERIENCED. NLM MJS
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #550454January 18, 2000FUEL SYSTEM, GASOLINE
DUAL GAS TANK FUEL SYSTEM OVER PRESSURIZED CAUSING GAS TO TRANSFER FROM ONE TANK TO ANOTHER RESULTING IN SPILLAGE. NLM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #550386January 13, 2000FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP
FUEL PUMP ASSEMBLY/CHECH VALVE FAILED CAUSING FUEL TO COME STREAMING OUT WHEN CONSUMER LOOSENED GAS CAP. NLM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0