Ford Contour Recalls
27 recalls on file.
- Recall97V203000November 17, 1997FUEL SYSTEM, OTHER:STORAGE
VEHICLE DESCRIPTION: BI-FUEL VEHICLES MODIFIED TO RUN ON EITHER GASOLINE OR COMPRESSED NATURAL GAS (CNG). THE NATURAL GAS FUEL TANKS HAVE A SOLENOID SHUT-OFF VALVE THAT STOPS FUEL FLOW FROM THE FUEL TANK IN THE EVENT OF CERTAIN MODERATE TO SEVERE COLLISIONS. IF THE VEHICLE IS IN A COLLISION AND THE NATURAL GAS FUEL LINE IS DAMAGED, THE SYSTEM COULD LEAK NATURAL GAS.
Remedy
FORD HAS REQUESTED OWNERS OF THESE VEHICLES TO HAVE THE CNG FUEL SYSTEM DISABLED UNDER A PREVIOUS RECALL CAMPAIGN AND TO ONLY USE GASOLINE FUEL UNTIL A PERMANENT CORRECTIVE ACTION IS DEVELOPED. OWNERS ARE BEING ALERTED TO THIS SOLENOID VALVE CONCERN AT THIS TIME. THE TIMING OF CORRECTIVE ACTIONS IS BEING DELAYED TO ALLOW BOTH CONDITIONS TO BE REMEDIED AT ONE TIME. IN THE MEANTIME, THERE IS NOT RISK AS LONG AS THE NATURAL GAS SYSTEM HAS BEEN DISABLED AND THE VHEICLE IS ONLY OPERATED ON GASOLINE.
- Recall95V232000December 5, 1995FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
THE FUEL TANK FILLER PIPE OPENING REINFORCEMENT, CONSTRUCTED FROM TWO SEPARATELY MOLDED PIECES, CAN LEAK AT THE WELD.
Remedy
DEALERS WILL REPLACE THE FUEL TANK ASSEMBLIES WITH UNITS CONTAINING ONE-PIECE MOLDED REINFORCEMENTS.
- Recall95V228000December 4, 1995SEAT BELTS:FRONT:ANCHORAGE
CRACKS HAVE BEEN FOUND IN THE FRONT SAFETY BELT OUTBOARD ANCHOR TABS DUE TO A COMBINATION OF HYDROGEN EMBRITTLEMENT OF THE TAB AND STRESS INTRODUCED DURING ATTACHMENT OF THE ANCHOR TAB TO THE SEAT FRAME. THIS DOES NOT CONFORM WITH THE REQUIREMENTS OF FMVSS NO. 210, "SEAT BELT ASSEMBLY ANCHORAGES."
Remedy
DEALERS WILL INSPECT AND INSTALL AN ANCHOR TAB REINFORCEMENT OR REPLACEMENT OF THE COMPLETE FRONT SEAT BELT ASSEMBLY IF AN ANCHOR TAB IS FOUND TO HAVE FRACTURED.
- Recall95E006002February 24, 1995AIR BAGS:FRONTAL
THE PASSENGER SIDE AIR BAG HAS AN INFLATOR BODY THAT CRACKED DURING FORMING OF THE CURL THAT RETAINS THE IGNITER PLUG IN THE END OF THE INFLATOR. ALSO THE IGNITER END CAP CAN SEPARATE FROM THE INFLATOR.
Remedy
DEALERS WILL REMOVE AND REPLACE THE PASSENGER SIDE AIR BAG MODULE.
- Recall95V009000January 24, 1995VISIBILITY:WINDSHIELD
THE GLASS TEMPERING PROCESS ON THE RIGHT HAND REAR DOOR WINDOWS WAS NOT CORRECTLY PERFORMED. THIS DOES NOT MEET THE REQUIREMENTS OF FMVSS NO. 205, "GLAZING MATERIALS."
Remedy
DEALERS WILL REPLACE THE RIGHT REAR DOOR GLASS.
- Recall94V203000October 18, 1994FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
THE FUEL TANK FILLER PIPE OPENING REINFORCEMENT CAN LEAK AT THE WELD.
Remedy
DEALERS WILL INSPECT AND, AS APPROPRIATE, REPLACE THE FUEL TANKS.
- Recall94V184000September 29, 1994FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
A METAL SHIELD ON THE OUTSIDE OF THE PLASTIC FUEL FILLER PIPE CAN DEVELOP A STATIC ELECTRICAL CHARGE DURING REFUELING OF THE VEHICLE.
Remedy
DEALERS WILL INSPECT AND, IF NECESSARY, MODIFY THE VEHICLES BY ADDING A GROUND STRAP BETWEEN THE FILLER PIPE SHIELD AND THE BODY.