Ford F-150 Complaints (1990)
275 consumer complaints on file.
- #727540August 10, 2000ELECTRICAL SYSTEM:IGNITION:SWITCH
THE IGNITION SWITCH WAS RECALLED IN 1996 BECAUSE IT WAS A FIRE DANGER. THE SWITCH WAS REPLACED AT THAT TIME. ON JULY 28, 2000 THE IGNITION SWITCH AGAIN CAUGHT ON FIRE. AT THAT TIME CHAMPION FORD REFUSED TO REPLACE IT UNDER THE RECALL. THEY STATED THAT THE RECALL HAD EXPIRED. THE SAME PART THAT HAD BEEN RECALLED DID THE SAME THING THE RECALLED PART WAS DOING. THE CHAMPION FORD DEALERSHIP SAID THAT THEY COULD NOT REPLACE THE PART FOR FREE BUT THAT IT WOULD COST $198.00. AFTER A DISCUSSION THEY TOOK $50.00 OFF OF THE PRICE, WHICH BROUGHT THE COST DOWN TO $148.00.*AK
- Crash:
- No
- Fire:
- Yes
- Injuries:
- 0
- Deaths:
- 0
- #727271August 9, 2000TIRES
THE TIRE TREAD COMPLETELY SEPARATED FROM THE RIM. I WENT TO THE FIRESTONE STORE AND THEY INSIST THIS IS NOT A DEFECT.( DOT NUMBER: )
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #866409July 31, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
FUEL TRANSFERS FROM FIRST TANK TO THE SECOND TANK, CAUSING FUEL LEAKAGE. PLEASE GIVE ANY FURTHER DETAILS.*AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #865552July 18, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A DEFECTIVE FUEL CHECK VALVE CAUSES THE FUEL TO SPILL ONTO THE 2ND FUEL TANK WHICH IT EXCEEDED AND CAUSED A FUEL SPILLAGE WHICH MAY RESULT IN A FIRE. THERE IS A RECALL 93V12500 FOR THIS PROBLEM. BUT THIS VEHICLE IS NOT AFFECTED BY THIS RECALL DUE TO VIN. *AK *ML
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #864766July 5, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
FUEL TANK LEAKS FUEL WHEN IT'S FULL. *AK *ML
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #863949June 21, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A MALFUNCTIONING CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY CAUSED A PORTION OF UNUSED FUEL FROM ONE TANK TO RETURN TO THE SECOND TANK, RESULTING IN FUEL SPILLAGE. A RECALL HAS BEEN ISSUED ON VEHICLE'S MAKE/MODEL. HOWEVER, THIS VEHICLE WAS NOT INCLUDED DUE TO VIN. THE MANUFACTURER HAS BEEN NOTIFIED. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #863993June 21, 2000ENGINE AND ENGINE COOLING:ENGINE
THE PICKUP TUBE THAT GOES TO THE OIL PAN BROKE, CAUSING ENGINE TO LOSE OIL AND LOCK UP. VEHICLE TOWED TO DEALERSHIP. MECHANIC INDICATED PROBLEM WAS CAUSED BY VIBRATION. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #863359June 9, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
COPPER PIECE ON THE FUEL TANK BROKE, CAUSING A FUEL LEAKAGE. MANUFACTURER SAID THEY DO NOT MAKE THAT PART ANY MORE. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #863196June 7, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:MOUNTING
FIRESTONE INSTALLED A NEW FUEL PUMP/SWITCH AND FUEL SENSOR. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #552283May 18, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
CONSUMER TOOK VEHICLE TO DEALER TO REPAIR MALFUNCTIONING CHECK VALVE WHICH CAUSED FUEL SPILLAGE, WHILE DRIVING HOME AFTER REPAIR CONSUMER NOTICE FUEL WAS STILL SPILLING OUT OF THE VEHICLE, CONSUMER FEELS VEHICLE WAS NOT REALLY REPAIRED. (93V-125) NLM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #552137May 4, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
RECALL 93V-125 OF THE CHECK VALVE WITHIN THE FUEL PUMP WAS REPAIR AND FAILED AFTER REPAIR CAUSING PORTIONS OF FUEL FROM ONE TANK TO BE PUMP TO THE SECOND TANK EXCEEDING THE CAPACITY OF THE SECOND TANK RESULTING IN LEAKAGE. YH
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #861155May 1, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY:FILLER PIPE AND CAP
WHEN USING THE REAR TANK, FUEL IS BEING PUMPED BACK INTO THE FRONT TANK. WHEN FRONT TANK IS FULL, FUEL BEING PUMPED FROM THE REAR TANK GOES INTO THE FRONT TANK WHICH CAUSES THE FRONT TANK TO OVERFLOW. RECALL ISSUED FOR THIS PROBLEM, BUT THIS VEHICLE NOT INCLUDED DUE TO VIN. *AK *ML
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #861025April 26, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A MALFUNCTIONING CHECK VALVE ALLOWS FUEL FROM ONE TANK TO TRANSFER TO SECOND TANK, CAUSING FUEL LEAKAGE. VEHICLE IS NOT INCLUDED IN RECALL 93V125000 DUE TO VIN. PLEASE GIVE ANY FURTHER DETAILS. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #9000511March 29, 2000ENGINE AND ENGINE COOLING:EXHAUST SYSTEM
SMELLED GAS IN GARAGE, REAR TANK DUMPING GAS IN MY FRONT TANK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #858965March 22, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. THE CAPACITY OF THE SECOND TANK CAN BE EXCEEDED, CAUSING FUEL SPILLAGE. DEALER HAS BEEN CONTACTED. PLEASE PROVIDE FUTHER INFORMATION. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #720036March 13, 2000WHEELS:LUGS/NUTS/BOLTS/STUDS
I WAS LUCKY THE TIRES WERE WOBBLING AND THE LUG NUTS WAS WORKING THEMSELVES LOOSE. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #718835February 16, 2000POWER TRAIN:AUTOMATIC TRANSMISSION
THE DESCRIBED TRUCK WAS PURCHASED BY MYSELF NEW. THE AAUTOMATIC TRANSMISSION HAD TO BE COMPLETELY REBUILT AT APPROX. 34,000 MILES(UNDER WARRANTY) . AT APPROX. 85000 MILES THAT TRANSMISSION BURNED OUT AND A "FORD FACTORY REBUILT " WAS INSTALLED AT EAST BAY TRUCK- OAKLAND CA. THE COST WAS APPROX. $2400.00 AS DESCRIBED, AT APPROX. 150,000 MILES THIS TRANSMISSION HAD TO BE REBUILT!!!! THE COST THIS TIME WAS APPROXIMATELY *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #550831February 9, 2000FUEL SYSTEM, GASOLINE:STORAGE:TANK ASSEMBLY
CHECK VALVE WITHIN THE FUEL PUMP ASSEMBLY FAILED PRIOR TO RECALL NOTICE CAUSING A PORTION OF THE UNUSED FUEL FROM ONE TANK TO BE RETURNED TO THE SECOND TANK. WHEN THIS OCCURS THE CAPACITY IS EXCEEDED CAUSING FUELL SPILLAGE. FUEL LEAK HAS CAUSED PAINT AND MOLDING DAMAGE. NLM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #550793February 8, 2000FUEL SYSTEM, GASOLINE:DELIVERY:FUEL PUMP
FUEL PUMP FAILED CAUSING FUEL TO LEAK FROM THE TANK WHEN THE PRESSURE BUILDS UP. NLM
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0
- #854926February 8, 2000FUEL SYSTEM, GASOLINE:STORAGE:AUXILLARY TANK:SELECTOR DEVICES
EA99023;DUAL FUEL TANK CROSS/FLOW.LEAKAGE; FUEL PUMPS FROM THE REAR TANK INTO THE FRONT TANK, CAUSING FUEL SPILLAGE WHEN BOTH TANKS ARE FILLED AND THE PUMP IS TURNED ON. PROLBEM WAS REPORTED TO THE DEALERSHIP. THE PROBLEM WAS NOT CORRECTED. *AK
- Crash:
- No
- Fire:
- No
- Injuries:
- 0
- Deaths:
- 0