2022-2023 Audi Q7/Q8 MIL Illuminated with DTC P060C00
This technical service bulletin (TSB) addresses instances where the Malfunction Indicator Lamp (MIL) illuminates on 2022-2023 Audi Q7 and Q8 vehicles, accompanied by diagnostic trouble code P060C00. Learn about the symptoms, diagnosis, and repair procedure.

También aplica a
- Audi Q7
- 2022–2023
- Audi Q8
- 2023
Owners of 2022-2023 Audi Q7 and Q8 models may encounter an illuminated Malfunction Indicator Lamp (MIL), commonly known as the "Check Engine" light. This condition is often accompanied by the storage of diagnostic trouble code (DTC) P060C00 in the vehicle's system. This technical service bulletin (TSB), identified as NHTSA Manufacturer Communication 10247509, provides guidance for technicians to diagnose and resolve this specific issue.
Symptoms
The primary symptom associated with this issue is the illumination of the Malfunction Indicator Lamp (MIL) on your dashboard. This warning light indicates that the vehicle's onboard diagnostic system has detected a fault within the engine or emissions control system. If you see the "MIL is illuminated" warning, it's important to have your vehicle inspected.
Fault Codes / DTCs
The specific diagnostic trouble code (DTC) associated with this bulletin is:
| Code |
|---|
| P060C00 |
This code points to an internal control module performance issue, specifically within the engine control unit (ECU) or a related component under the ENGINE AND ENGINE COOLING category.
Diagnosis and Repair Information
NHTSA Manufacturer Communication 10247509 provides detailed information for technicians to diagnose the root cause of the illuminated MIL and the stored DTC P060C00. The bulletin outlines the necessary steps to identify the precise fault and perform the appropriate repair. While specific repair steps are not detailed in the summary, the bulletin serves as a comprehensive guide for addressing this particular engine control issue.
What Owners Should Do
If you own a 2022-2023 Audi Q7 or Q8 and your Malfunction Indicator Lamp (MIL) is illuminated, especially if a scan reveals the DTC P060C00, it is recommended to contact your authorized Audi dealership. Inform them about the illuminated MIL and the diagnostic trouble code. Reference NHTSA Manufacturer Communication 10247509, as this bulletin contains the necessary information for technicians to properly diagnose and rectify the Audi Q8 MIL P060C00 issue.
NHTSA ID: 10247509
Frequently Asked Questions
- What does DTC P060C00 mean for my Audi Q8?
- DTC P060C00 indicates an internal control module performance issue, typically related to the engine control unit. When this code is stored, it often triggers the Malfunction Indicator Lamp (MIL) on your dashboard.
- Is there a fix for the illuminated MIL on my 2022-2023 Audi Q7?
- Yes, NHTSA Manufacturer Communication 10247509 provides diagnostic and repair information for technicians to address the illuminated MIL and DTC P060C00 on 2022-2023 Audi Q7 and Q8 vehicles. Your Audi dealership can access this bulletin for the appropriate repair.
- How do I get my Audi Q8 MIL P060C00 issue resolved?
- If your 2022-2023 Audi Q8 has an illuminated MIL and the DTC P060C00, you should schedule an appointment with an authorized Audi service center. They will use the information provided in NHTSA Manufacturer Communication 10247509 to diagnose and fix the problem.
Otras revisiones de este TSB
- 2022-2024 Audi Q5 / A4 EPC Light and Drive System Fault TSBP060C00
- 2022-2024 Audi Q5 / A4 / A5 Engine Faults P060C00 U041600P060C00
- 2022-2025 Audi A4, A5, Q5 Engine Control Unit Faults P060C00, U041600P060C00
- 2022-2025 Audi A4/Q5 Drive System Fault P060C00 U041600 TSBP060C00
- 2022-2024 Audi Q5 EPC Light P060C00 U041600 TSBP060C00
- 2022-2025 Audi A4, A5, Q5 Engine Control Unit FaultsP060C00
- 2022-2024 Audi Q5 EPC Light P060C00 U041600 TSBP060C00
- 2022-2024 Audi A4/A5/Q5 Lineup Engine ECU Faults P060C00 U041600P060C00
Related Articles
2021-2024 Audi Coolant Pump Leak & DTC P0299 TSB
This Audi Technical Service Bulletin 2070349/6 addresses coolant loss, warning lights, and DTC P0299 related to the mechanical coolant pump in 2021-2024 Audi models with 2.9L or 3.0L V6 TFSI engines. Learn about symptoms, diagnosis, and repair procedures.
2021-2026 Audi Q8 Rear Compartment Noise TSB 2067759/4
Audi has issued Technical Service Bulletin (TSB) 2067759/4 for 2021-2026 Audi Q8 vehicles experiencing a ticking or thumping noise in the rear passenger compartment, especially at idle. The noise is caused by vibrations from the activated charcoal filter solenoid valve (N80) against the EVAP line.
2021-2026 Audi Tensioner Part Number Update SM 63-2025
Audi Special Notice SM 63-2025 informs dealers about an updated tensioner part number. Old part 059-109-467-BB must be returned by December 16, 2025, and replaced with new part 059-109-467-BD to ensure proper inventory.
2022-2024 Audi MLBevo Emergency Call System Warning TSB
Audi Technical Service Bulletin 2079649/1 details a software issue causing an 'Emergency call function: fault' warning in the instrument cluster of 2022-2024 MLBevo vehicles. This TSB provides a software update solution for intermittent communication errors.
2022-2025 Audi Q7/Q8 Third Row Seat Malfunction TSB
Owners of 2022-2025 Audi Q7, SQ7, Q8, SQ8, and RS Q8 vehicles may experience a third row seat malfunction where seats do not fold or lock. Audi TSB 2079211/1 explains this is often due to external blockages and is not covered under warranty.
Leave a comment
Comments are moderated and may take a moment to appear. Only your first name and the initial of your last name are shown publicly.
Comments
Be the first to comment.